B. Maxstar 400 Models
.
Do not use information in unit specifications table to determine electrical service requirements. See Section 5-14B for information on connecting
input power.
Welding Amperage
Range
3-400*
*Welding range for Stick process is 5-400 amperes. For TIG, the amperage range is tungsten diameter dependent (see Section 6-3).
** Arc starting device is designed for manual guided operations.
*** Low open-circuit voltage while in TIG Lift Arct, or while in Stick with low open-circuit voltage selected.
♦ Normal open-circuit voltage (75) is present while in Stick with normal open_circuit voltage selected.
Rated Welding
Input Power
Output
250 A @ 30 Volts,
100% Duty Cycle
300 A @ 32 Volts,
Three Phase
60% Duty Cycle
400 A @ 36 Volts,
20% Duty Cycle
200 A @ 28 Volts,
100% Duty Cycle
250 A @ 30 Volts,
Single Phase
60% Duty Cycle
300 A @ 32 Volts,
20% Duty Cycle
.
This unit is equipped with Auto-Linet
primary input voltage from 190 to 625 volts, single-or-three-phase, 50 or 60 hertz. Also adjusts for voltage spikes within the entire range.
C. Dynasty 800 Models
.
Do not use information in unit specifications table to determine electrical service requirements. See Section 5-14 A for information on connecting
input power.
Welding Amperage
Range
5-800*
*Welding range for Stick process is 5-750 amperes. For TIG, the amperage range is tungsten diameter dependent (see Section 6-3).
** Arc starting device is designed for manual guided operations.
*** Low open-circuit voltage while in TIG Lift Arct, or while in Stick with low open-circuit voltage selected.
♦ Normal open-circuit voltage (75) is present while in Stick with normal open_circuit voltage selected.
Rated Welding
Input
Power
Output
500 A @ 40 Volts,
100% Duty Cycle
600 A @ 44 Volts,
Three
60% Duty Cycle
Phase
800 A @ 44 Volts,
20% Duty Cycle
400 A @ 36 Volts,
100% Duty Cycle
Single
Phase
500 A @ 40 Volts,
60% Duty Cycle
.
This unit is equipped with Auto-Line
primary input voltage from 190 to 625 volts, single-or-three-phase, 50 or 60 hertz. It also adjusts for voltage spikes within the entire range.
.
A complete Parts List is available at www.MillerWelds.com
Max Open Circuit
Low Open-Circuit
Voltage (Uo)
Voltage (Uo)
75
208 V
230 V
26
23
33
30
50
45
37
33
48
43
62
55
.
Auto-Line is an internal inverter power source circuit that automatically links the power source to any
Max Open Circuit
Low Open-Circuit
Voltage (Uo)
Voltage (Uo)
75
208 V
230 V
73
66
96
86
118
123
98
88
136
122
.
Auto-Line is an internal inverter power source circuit that automatically links the power source to any
Rated Peak Striking
Voltage (Up)
10-15***
14KV**
Amperes Input at Rated Load Output 50/60 Hz
380 V
400 V
460 V
14
13
18
17
27
25
18
24
30
Rated Peak Striking
Voltage (Up)
10-15***
14KV**
Amperes Input at Rated Load Output 50/60 Hz
380 V
400 V
460 V
39
37
51
48
69
65
48
66
IP Rating
23
575 V
KVA
12
9
9.4
15
12
12
22
17
18.1
18
12
7.4
20
16
10.0
28
20
12.8
IP Rating
23
575 V
KVA
32
25
26.3
42
33
34.7
57
45
46.9
41
32
20.2
56
44
28.0
OM-275857 Page 13
KW
9.1
11.6
17.3
6.9
9.2
11.8
KW
25.2
33.2
45.0
18.6
25.8

Advertisement