Commissioning, inspection, maintenance
Commissioning the system with the commissioning...
Commissioning assistant
sequence
Commissioning
"C.1"
Filling program
"C.2"
Venting program
"C.3"
*1
Gas type
"C.5"
*1
Flue system
"C.6"
*1
Flue length
"C.7"
Operating mode
*1
This setting is not required for appliances with multiple connection "M".
The gas type is preset to natural gas; the flue system and flue pipe length are automatically set correctly via the integral
mass flow correction.
34
Explanations and references
ON = on
OFF = off
Note
It is possible to interrupt or end the process while a rotating rectangle alternat-
ing with the current system pressure is displayed; to do so, press
ON = on
OFF = off
Note
It is possible to interrupt or end the process while a rotating rectangle alternat-
ing with the current system pressure is displayed; to do so, press
2 - Natural gas
3 - Liquid gas LPG
1 - Open flue 60 mm, rigid
2 - Room sealed 60/100 mm, rigid
3 - Open flue 80 mm, rigid
4 - Room sealed 80/125 mm, rigid
5 - Flexible 60 mm (room sealed or open flue) max. 10 m
6 - Flexible 80 mm (room sealed or open flue) max. 20 m
Given in full metres (round up if necessary)
Note
An additional length of 1 m must be factored in for every flue bend.
1 - Constant operation with time program
4 - Weather-compensated
13 - Constant operation with optional room thermostat
14 - OpenTherm
15 - Individual room control
16 - Individual room control with modulation
Note
Operating modes 15 and 16 can only be set via the software tool.
If operating mode 15 or 16 is set, low power radio cannot be switched off!
(cont.)
for 3 s.
for 3 s.