Page 1
Version 1.0 October 2009 The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the CP-3216PROC. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the device.
Page 3
IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “Dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (Servicing) instructions in the literature accompanying the product.
Page 4
WARNING Changes or Modifications not expressly approved by Evertz Microsystems Ltd. could void the user’s authority to operate the equipment. Use of unshielded plugs or cables may cause radiation interference. Properly shielded interface...
Page 5
Evertz products are for informational use only and are not warranties of future performance, either express or implied. The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty, stated in the sales contract or order confirmation form.
Page 6
CP-3216PROC Programmable Video/Audio Proc Control Panel This page left intentionally blank Page ii Revision 1.0...
CP-3216PROC Programmable Video/Audio Proc Control Panel TABLE OF CONTENTS 1. OVERVIEW .........................1 2. INSTALLATION ........................2 2.1. REAR PANEL..........................2 2.2. FRONT CONTROL PANEL....................... 3 3. TECHNICAL DESCRIPTION....................4 3.1. SPECIFICATIONS........................4 3.1.1. Control ..........................4 3.1.2. Power..........................4 3.1.3. Physical ..........................4 4.
Page 8
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.4. BUTTONS TAB ........................18 5.4.1. Assigning a Service Template to a Button................ 20 5.5. IMPORT/EXPORT TAB ......................20 5.5.1. Exporting a Configuration to Use on Other Panels ............21 5.5.2. Importing a Configuration to Use on Other Panels ............21 5.6.
CP-3216PROC Programmable Video/Audio Proc Control Panel OVERVIEW The CP-3216PROC control panel is an optimized solution for video and audio proc applications. The CP-3216PROC features sixteen rotary shaft encoders for quick simultaneous access to sixteen unique video and audio proc control parameters. The CP-3216PROC also features an array of thirty-two dynamic LCD buttons.
CP-3216PROC Programmable Video/Audio Proc Control Panel INSTALLATION 2.1. REAR PANEL Figure 2-1 shows the rear view of the CP-3216PROC control panel. The following is a list of the ports and controls on the rear panel: Figure 2-1: CP-3216PROC Rear Panel IEC POWER: These two connectors are used for main and redundant supply of power to the CP-3216PROC.
CP-3216PROC Programmable Video/Audio Proc Control Panel 2.2. FRONT CONTROL PANEL The CP-3216PROC has both rotary encoders and programmable LCD buttons on its front panel. There are a total of 16 rotary shaft encoders and a total of 32 programmable LCD buttons. Rotary encoders are used to adjust card parameters.
CP-3216PROC Programmable Video/Audio Proc Control Panel FRONT PANEL CONTROL To enter the setup menu of the CP-3216PROC press and hold rotary encoders (R1 and R16) on the far left side and far right side of the panel for approximately 6 seconds. You will then be presented with five LCD buttons that are used to navigate the engineering menus.
CP-3216PROC Programmable Video/Audio Proc Control Panel 4.1.2. Setting the IP Address of the Control Panel The IP menu item is used to set the IP address of the CP-3216PROC control panel. The IP address is formatted in the following way aaa.bbb.ccc.ddd To set the IP address, rotate encoder R2 through R5 to change the IP address values.
CP-3216PROC Programmable Video/Audio Proc Control Panel 4.1.5. Setting the Gateway The Gtw menu item is used to set the gateway address for the CP-3216PROC control panel. The gateway address is formatted in the following way aaa.bbb.ccc.ddd To set the gateway, rotate encoder R2 through R5 to change the gateway values. R2 controls “aaa”...
CP-3216PROC Programmable Video/Audio Proc Control Panel 4.2.1. Performing a SHAFT Test Pushing the SHAFT test button enables the user to enter the test mode that tests the rotary encoders of the CP-3216PROC control panel. When this is done, buttons B1 to B16 will light up in a purple colour and show two numerical values in each button (one on top of the other).
1. The user must have a laptop or PC connected to the same network as the CP-3216PROC. 2. The user must obtain upgrade files from Evertz Personnel. a. Your computer must be running the Mozilla firefox web browser located at: http://www.mozilla.com/en-US/firefox/...
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.1.3. Upgrading Firmware on the CP-3216PROC 1. To upgrade firmware using the web interface, open a firefox web browser and enter the IP address of the CP-3216PROC, then press the <enter> key. The CP-3216PROC screen will appear, as shown in Figure 5-1.
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.1.4. Navigating to the Panel Configuration Page The user can configure the CP-3216PROC using the Control Panel Configuration Web Interface. To access the Configuration Web Interface for the CP-3216PROC, follow the instructions outlined below: 1.
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.2. UPLOAD PRODUCTS TAB The Upload Products tab allows the user to upload xml product files to the control panel. Uploading the product files will provide access to the specific product parameters and enable configuration. Figure 5-3: Upload Products Tab The Upload Products page has two control buttons, which are listed below: •...
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.3. SERVICE TEMPLATES TAB A Service Templates tab enables the user to create a template, which can be loaded onto the CP- 3216PROC control panel. This template defines and assigns button functions to the control panel buttons.
CP-3216PROC Programmable Video/Audio Proc Control Panel Once a template is selected or the user creates a new template, a new template page will appear (as shown in Figure 5-6) enabling the user to assign parameters to the sixteen rotary encoders. Figure 5-6: Customizing a Template 5.3.1.
CP-3216PROC Programmable Video/Audio Proc Control Panel • Show Details: Pressing the Show Details button will toggle the content of the Parameter field. When the user presses the Show Details button, the path of the parameter and the abbreviated name will be displayed in the Parameter field (ie. VideoControl >...
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.3.3. Rotary Dial Properties The user can adjust the properties of each dial by entering the appropriate information into the fields below: • Dial: This field identifies the dial number. • Parameter: This field identifies the parameter name and displays the location of the parameter in the parameter tree (when the Show Details button is selected).
CP-3216PROC Programmable Video/Audio Proc Control Panel Figure 5-9: Assigning a Parameter to a Rotary Encoder 4. For each parameter that is applied to a dial, the user can fill in the five properties displayed (ie. dial, parameter, short name, default, and increment). 5.
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.4. BUTTONS TAB The Buttons tab enables the user to set the parameters for the associated buttons. Using the Buttons tab, the user can assign a service template to a button. Doing this enables the user to successfully, set and control parameters for specific cards and frames.
CP-3216PROC Programmable Video/Audio Proc Control Panel There are three page controls listed under the Buttons tab. The page controls include: Button Image Description Add Page The Add Page button enables the user to add a new page to the screen. The Duplicate Page button enables the user to copy the properties of the Duplicate Page current page and create a replica of that page.
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.4.1. Assigning a Service Template to a Button 1. Navigate to the Buttons control tab. 2. For each button, click on the Services Template box and begin typing the name of the Service Template that you want to assign that button to. The name of the service template will start to appear automatically.
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.5.1. Exporting a Configuration to Use on Other Panels To export a configuration, follow the instructions outlined below: 1. Navigate to the Import/Export control tab and select the Export button. 2. An export dialog box will appear, as shown in the Figure 5-14. Save the file in a known location. Figure 5-14: Exporting File 5.5.2.
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.6. OTHER SETTINGS TAB The Other Settings tab enables the user to control the refresh rate of the module and the parameter. Figure 5-15: Other Settings Tab The following settings can be controlled: • Module Refresh Rate: This parameter enables the user to set the rate at which the module refreshes.
CP-3216PROC Programmable Video/Audio Proc Control Panel 5.7. CONNECTING THE CP-3216PROC TO A FRAME OF EQUIPMENT 1. Ensure that the panel and the frames to which it needs to communicate with are on the same subnet. 2. The control panel should automatically discover all cards in the frame. 3.
Page 32
CP-3216PROC Programmable Video/Audio Proc Control Panel This page left intentionally blank Page 24 Revision 1.0...
Need help?
Do you have a question about the CP-3126PROC and is the answer not in the manual?
Questions and answers