"THERMAL DISINFECTION CYCLE" FUNCTION (ANTI-LEGIONELLA)
The antibacterial function is activated by pressing the MODE button for 3 seconds. All the temperature LEDS are
switched off during activation, with the sole exception of the 60° LEDS, which flash. Similarly, all the LEDS switch off
during deactivation, with the exception of the 40° LED, which flashes.
The antibacterial function heats the water to avoid the formation of bacteria in the internal tank. The antibacterial
function is performed when the machine is switched on (with supercap empty) or 30 days (depending on the NFC
parameter settings) after the last time that the antibacterial condition was considered to be satisfied: this occurs when
the average water temperature has been higher than the antibacterial setpoint for a certain period (this depends on
the NFC, but the antibacterial cycle is usually performed at 65° C to guarantee that the temperature is higher than 60°
C for 1 hour).

TECHNICAL CHARACTERISTICS

For the technical specifications, refer to the nameplate (the nameplate is located next to the water intake/outlet pipes).
Table 1 - Product information
Product range
Weight (kg)

Installation

Model
SMART
Qelec (kWh)
Qelec, week, smart (kWh)
Qelec, week (kWh)
Load profile
L
wa
wh
V40 (L)
Capacity (l)
The power consumption data in the table and the other information given in the Product Data Sheet (Enclosure A to this
manual) are defined in relation to EU Directives 812/2013 and 814/2013.
The products without the label and the data sheet for water heaters and solar devices, stipulated in regulation 812/2013,
are not intended to be used in such assemblies.
The device is equipped with a smart function that allows you to adapt the consumption to the user profiles. If operated
correctly, the device has a daily consumption of "Qelec* (Qelec,week,smart/Qelec,week)" less than that of an equivalent
product with no smart function".
This appliance is conforming with the international electrical safety standards IEC 60335-1 and IEC 60335-2-21.
The CE marking of the appliances attests its conformity to the following EC Directives, of which it satisfies the
essential requisites:
- LVD Low Voltage Directive: EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106.
- EMC Electro-Magnetic Compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
- RoHS2 Risk of Hazardous Substances: EN 50581.
- ErP Energy related Products: EN 50440.
This product is in conformity with REACH regulations.
14
50
80
17
22
Vertical
Vertical
Refer to the nameplate
X
X
6,893
7,323
24,558
25,435
29,678
32,942
M
M
15 dB
40,0%
40,0%
65
92
49
75
100
26
Vertical
X
7,455
26,002
33,778
M
40,0%
130
95

Advertisement

Table of Contents
loading

Table of Contents