Advertisement

Quick Links

Cod. 252.180.11
FRY – TOP GAS - SERIES 7
MOD. 70-40 FTG
70-40 FTRG
70-40 FTGS
70-70 FTG
70-70 FTRG
70-70 FTGS
70-70 FTRRG
70-40 FTG – CR
70-40 FTRG – CR
70-70 FTG – CR
70-70 FTRG – CR
70-70 FTRRG – CR
~
70-40 FTG-T
70-40 FTRG-T
70-40 FTGS-T
70-70 FTG-T
70-70 FTRG-T
70-70 FTGS-T
70-70 FTRRG-T
70-40 FTG-CR-T
70-40 FTRG-CR-T
70-70 FTG-CR-T
70-70 FTRG-CR-T
70-70 FTRRG-CR-T
~
¸
GB-IE– CAT. II
2H3+

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 70-40 FTG and is the answer not in the manual?

Questions and answers

Summary of Contents for mastro 70-40 FTG

  • Page 1 GB-IE– CAT. II 70-70 FTRG 70-70 FTRG-T 2H3+ 70-70 FTGS 70-70 FTGS-T 70-70 FTRRG 70-70 FTRRG-T 70-40 FTG – CR 70-40 FTG-CR-T 70-40 FTRG – CR 70-40 FTRG-CR-T 70-70 FTG – CR 70-70 FTG-CR-T 70-70 FTRG – CR 70-70 FTRG-CR-T 70-70 FTRRG –...
  • Page 2 INDEX Warnings Compliance with “EEC” Directives for gas appliances Installation diagrams Technical data table / Fry-Top Gas characteristics Instructions for the qualified installer Appliance installation Laws, technical regulations and general rules Discharge of fumes for type ”A” appliances Checking for gas leaks Maintenance Conversion for use with a different type of gas / Fry-Top Changing spare parts...
  • Page 3 THIS APPLIANCE HAS BEEN MADE FOR COOKING FOOD AND MUST ONLY BE USED BY PROFESSIONALLY SKILLED PERSONNEL IN THE WAY DESCRIBED IN THIS INSTRUCTION MANUAL. WARNINGS • Read this handbook through carefully as it provides important information for safe installation, use and maintenance. •...
  • Page 4: Technical Data Table

    POWER NATURAL NATURAL MODEL G30 – G31 G30 – G31 No. x kW kg/h 30mbar 37mbar m³/h 20 mbar 70-40 FTG 70-40 FTRG 70-40 FTG-CR 1 x 5.7 0.443 0.603 70-40 FTRG-CR 70-40 FTGS 70-70 FTG 70-70 FTRG 70-70 FTRRG 2 x 5.7...
  • Page 5: Gas Characteristics

    GAS CHARACTERISTICS The data relative to powers and consumption refer to the following types of gas: TYPE OF GAS NET HEAT VALUE PRESSURE SUPPLY (NHV) mbar mm water 9.45 kW m³/h (natural gas) 12.68 kW/kg (butane) 12.87 kW/kg (propane) 8.12 kW m³/h (G20L –...
  • Page 6: Checking For Gas Leaks

    DISCHARGE OF FUMES FOR TYPE “A” APPLIANCES The appliances must be installed on premises that are suitable for the discharge of the combustion products and must comply with the installation rules. Our appliances are considered type “A” gas appliances (see the Technical Data Tables) and are not for connecting to a natural discharge duct for combustion products.
  • Page 7 CONVERSION FOR USE WITH A DIFFERENT TYPE OF GAS – FRY TOP The appliance is tested and set for working with gas according to the characteristics table affixed in proximity to the appliance’s gas inlet. In order for it to function with a different type of gas, proceed as follows: The conversion must be carried out by qualified personnel •...
  • Page 8 CHANGING SPARE PARTS Safety cock (6): remove the panel (12), unscrew the nut connecting the cock to the supply shaft (9) and to the burner supply pipe, unscrew the thermocouple (15) and the pilot pipe (16) from the cock, change the cock. Thermocouple (15): remove the panel (12), unscrew the thermocouple (15) from the cock (6) and from the pilot support (18) and then change it.
  • Page 9 INSTRUCTIONS FOR USE OF THE THERMOSTATIC MULTIGAS COCK PEL 25 ST FOR THE CHROME FRY-TOP To light the burner, connected to the cock, push the knob until it will go no further and then turn it in the direction of the arrow, round to the “PILOT”...
  • Page 10: Maintenance, Cleaning And Care

    MAINTENANCE, CLEANING AND CARE Always disconnect the appliance from the gas supply before embarking on any maintenance work. FRY – TOP MAINTENANCE There is very little maintenance to do thanks to the correct way the appliances have been made. However, we do advise having the systems checked by qualified personnel at least twice a year.
  • Page 11 EXPLODED FUNCTIONAL PARTS TABLES 10.1 Exploded tables of normal Fry-Tops Mod.70-40 FTG 70-40 FTG-T 70-40 FTRG 70-40 FTRG-T FIG. 1 70-40 FTGS 70-40 FTGS-T 70-70 FTG 70-70 FTG-T 70-70 FTRG 70-70 FTRG-T 70-70 FTRRG 70-70 FTRG-T 70-70 FTGS 70-70 FTGS-T FIG.
  • Page 12 10.2 EXPLODED TABLES OF CHROMED FRY-TOPS FIG. 2 BILD 2 MOD. 70/40 FTG-CR 70-40 FTG-CR-T 70/40 FTRG-CR 70-40 FTRG-CR-T 70/70 FTG-CR 70-70 FTG-CR-T 70/70 FTRG -CR 70-70 FTRG-CR-T 70/70 FTRRG-CR 70-70 FTRRG-CR-T 10 11 7 6 19 FIG. 5 BILD 5 POSIZIONE CHIUSO (SPEGNIMENTO) FERME' GESCHLOSSEM.

Table of Contents