PROGRAMMING
BURGLARY LOOPS:
If the silent burglary alarm option has not been selected, violating a butgldry loop
Sound,
continuously for 1 -Id minutes (ns
progranmted)
Violntlng."
the Arm light blink and the violation displayed on the SCS until a valid disarm code is entered. Entering
valid disarm code will also silence the alarm.
EXIT/ENTRY- TYPE 0. the Exit/Entry Loop is the standard delayed burglary loop. It
^
alarm if violated during the exit delay after arming the system. Later, when the user returns andvrol»
rZp. there will be a delay (entry time) before the alarm will be tripped. DuringjjU» dWay' time
system normally sounds a warning tone over the SCS beeper. Disarmmg the ttystem before iJ, and of toe
entry11time prevents an alarm.
The alarm will trip if the system is not d,canned m bn,revert,f toe
ExibEntry Loop has been restored. The loop which starts the entry tune is rememberedfor
alarm mmnory
Exit/Entry Loops are Used on exterior doors, other common points of entry, of anywhere
timfc delay before alarm is desired.
SFCONDARY DELAY- TYPE 1.
The Secondary Delay Loop is a burglary loop which is not enabled
LtnTe
loop
is mad, good after the end of the exit time. One can arm into a violated Secondary Deby
Loop Withou tripping an alarm. Upon return, violating the Secondary Delay Loop will start an entry^titfte
wS can be programmed to be different from the normal entry time. Tfre secondary
tjme*n be
programmed to be as long as 4 minutes. The Secondary Delay Loop ts normally used for garage doors.
INSTANT-TYPE 2
The
Instant Loop is the standard burglary loop. It will trip an alarm instantly if
violated while the system is armed.
Instant Loops are normally used for window sensors and other
protected areas that are not a common point of entry.
NOMAD- TYPE 3. The Nomad Loop is a burglary loop which is automatically disabled during the entry
and exit times but does not by itself initiate an entry time. At all other times it performs ^"d°^r
This type of loop is sometimes referred to as a Follower Loop.
The nomad loop is normally
usfcd
for
interior^protectiort Since otie edrt go through it when walking between the SCS and the exit/entry doo .
Nomad Loops cari replace instant loops in many applications.
If the force nomad optioh is enabled, the panel can be armed with the nomad zones violated. If a nomad
zone is violated before or at the end of the exit time, 10 additional seconds will be added to the exit time
duration. If the nomad zories are Still violated after this period, the alarm will sound.
DAY/NIGHT: TYPE 4. A Day/Night Loop is a burglary loop which initiates a trouble signal if violated
While the system is disarmed. Trouble is displayed on the SCS but the status willshow^ ready- If the loop
violated aUhe time of ahning it will automatically be bypassed. Restoring the Day/Night Loop while the
system is armed will have the system fully armed. Upon the next violation of the D/Nzone, the zonew.ll
act as an instant zone and go into alarm. If the loop Was good at time of arming then it will act as an
Instant Loop
Day/Night Loops are normally used for window foil which may open during the day as the
££expands and resL in the cool of the night. If the D/N *>ne is programmed in the Line Cut Monitor
and the telephone line is disconnected during the disarmed state, only the Line Cut segment is displayed
and not the zone violation.
MEDICAL: TYPE 5. the Medical Loop is a 24 hour loop which sounds the SCS beeper and reports to the
AMC. The medical alarm is cleared by entering a valid disarm code. The medical loop is used to summon
paramedics or the like for serious medical emergencies.