Download Print this page

Specifications - BRINKS BHS 2000A Installation & Programming Manual

Advertisement

BHS-2000A
SPECIFICATIONS
Operating Voltage: 16.5 VAC , 20 or 25 VA, Class 2 Plug in Transformer
Standby Power: 12VDC , 4AH Gel Cell (YuasaNP4-12) or 12 VDC , 8AH Gel Cell (Power-sonic
PS-1282L)
Alarm output: Internal Siren Driver. 4 ohms maximum.
Bell output: 12 VDC output. 400 mA max. using a 20VA transformer. 500 mA max. using a 25 VA
transformer.
Digital Communicator: Pulse or DTMF dialing
Reporting format: SIA
FCC Registering: AB7USA-18685-AL-E
Ringer Equivalence: 0.6B
DOC Certification: 524-5178A
OOC Load number: 17
Zone Specifications: 8 Supervised zones. 3mA maximum zone current. RFI and Transient Suppression
Built in.
Auxiliary and Fire Power: 12.5 VDC at 330 mA (20VA). 12.5 at 500mA(25VA).
System test: Automatic and/or User initiated at the SCS.
Enclosure: Alarm Control Panel (ACP), 20 Gauge steel.
System Control Station (SC) - high impact ABS plastic
Operating Temperature: 32- 120 deg. F
Dimensions: BHS-2000A
9"W x 13"L x 3"D
DCU-602B
6 3/8"W x 4 11/16" Lx 1"D

Advertisement