If the tank is overfilled, the pressure discharge will be blocked to prevent fuel from being forced
through the pressure relief valve into the unit's tray. In this case, you will see the following message:
After the start-up process, the device changes to normal mode and you can now call up the menu by
activating 'Mode'. For example, you will see this first standard display:
'bar' is the displayed pressure unit. Here psi or bar can be selected in the menu. 'C0' means the
pressure control is switched off. P0' means the pumps are currently off.
Later, when you have activated the pressure control, you will see 'C1' in the display. Depending on
whether the pumps are currently on or off, either 'P0' for 'Pumps off' or 'P1' for 'Pumps on' is shown.
The pumps can only be switched on if the pressure control is on.
Use 'Up' and 'Down' to navigate between the following standard displays:
You can access the menu from any standard display.

22 Switching on the Flame Heads and safety timer

The Flame Heads are turned on by moving the main switch on the Pump Station to the 'on' position.
WARNING
2.2.2
2.3.4
2.4.2
38
This process takes a few seconds.
In this case, you should pump fuel out of the tank. You can achieve this
with the corresponding menu item.
'SV' stands for setpoint value of the pressure. You can adjust this
setpoint in the menu. 'AV' Means actual value. Here the device
continuously measures the actual pressure and displays it.
As long as the fuel level in the tank has not yet been measured, you
will see this display. Otherwise, you will see the result of the last level
measurement instead.
It is planned that the Flame Heads transmit information about their
status to the Pump Station. With this firmware version this is not yet
possible and you will see this placeholder display.
If faults are detected, they will be displayed here.
Unintentional triggering of a flame column
Technical faults can lead to unintentional flame effects.
Make sure that the required safety distance to persons is
maintained.
Only connect the fuel-carrying lines when they the device is
switched off.
Minimize the presence in the danger zone.
Enable the flame monitoring system.
Never keep body parts above the combustion chamber at any
time.
Follow all safety instructions and regulations at all times.