6.2 Fitting the supporting feet (4)
Fit the supplied supporting feet (4) as shown in
6.3. Replacing the oil sealing plug (14)
Remove the transportation cover from the oil filler
opening with a screwdriver and insert the suplied oil
sealing plug (14) into the oil filler opening(Fig.6)
6.4. Fitting the air filter (1)
Use a screwdriver to remove the transportation cover from
the air filter connection
Screw in the supplied air filter (Fig8)
6.5. Power supply
-The motor is fitted with an overload switch
Fig. 3/Item 6) If the compressor overloads, the overload
(
switch switches off the equipment automatically to protect
the compressor from overheating. If the overload switch
triggers, switch off the compressor using the ON/OFF
Switch (8) and wait until the compressor cools down. Then
press the overload switch(16) and restart the compressor.
Long supply cables, extensions, cable reels etc. cause a
-
drop in voltage and can impede motor start-up
- In the case of low temperatures below+5℃, motor
start-up is jeopardized as a result of stiffness
6.6. On/Off switch (8)
To switch off the compressor, press the On/Off (8)
To switch off the compressor, press the On/Off switch
(8) in again. (Fig.2)
6.7 Adjusting the pressure: (Fig. 1,2)
-
You can adjust the pressure on the pressure gauge (6)
using the pressure regulator (7)
-
The set pressure can be taken from the quick-lock coupling
(5)
6.8 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 8 bar
Switch-on pressure 10 bar
7. Replacing the power cable
Danger!
If the power cable for this equipment is damage
d,it must be replaced by the manufacturer or its
after-sales service or similarly trained personal
to avoid danger.
Fig. 6
8. Cleaning, maintenance andordering of spare
parts
Danger!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Warning!
Wait until the compressor has completelycoole
d down. Risk of burns!
Warning!
Always depressurize the tank before carryingou
t any cleaning and maintenance work.
Warning!
After use, always switch off the equipmentimm
ediately and pull out the power plug.
8.1 Cleaning
-Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at
low pressure.
- We recommend that you clean the appliancei
mmediately after you use it.
- Clean the appliance regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may beaggres
sive to the plastic parts in the appli-
ance. Ensure that no water can get into theinter
ior of the appliance.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensation water (Fig. 1)
Notice! To ensure a long service life of the pres-
sure vessel (2), drain off the condensed water b
yopening the drain valve (11) each time after us
ing.Check the pressure vessel for signs of rust a
nddamage each time before using. Do not use
compressor with a damaged or rusty pressureve
ssel. If you discover any damage, please con-
tact the customer service workshop.