Selecting The Installation Location - Mitsubishi Electric MXZ-3A30NA Installation Manual

Hide thumbs Also See for MXZ-3A30NA:
Table of Contents

Advertisement

1-4. SELECTING
PIPE SIZE AND OPTIONAL DIFFERENT-DIAMETER JOINTS
The diameter of connection pipes differs according to the type and capacity of indoor units. Match the diameters of connection pipes for indoor and outdoor
units according to the following table.
«
Ifthe diameter of connection pipes does not match the diameter of pipe end connections, use optional different-diameter joints.
[mm (inch)]
Indoor unit
Outdoor unit
=
:
09/12
15/17
24
ipe size
(liquid / gas)
6.35 (1/4)
/ 9.52 (3/8)
6.35 (1/4) / 12.7 (1/2)
6.35 (1/4) / 15.88 (5/8)
AUNIT
6.35 (1/4) / 12.7 (1/2)
~ /MAC-A455JP
-f-
-/ MAC-A456JP
B UNIT
C UNIT
6.35 (1/4) / 9.52 (3/8)
~/-
~/ MAC-454JP
-/ PAC-SG76RJ
D UNIT *
* MXZ-4A36NA only
1-5. SELECTING THE INSTALLATION LOCATION
+
Where it is not exposed to strong wind.
+
Where airflow is good and dustless.
+
Where rain or direct sunshine can be avoided as much as possible.
+
Where neighbours are not annoyed by operation sound or hot air.
+
Where
rigid wall or support is available to prevent the increase of op-
eration sound or vibration.
+
Where there is no risk of combustible gas leakage.
+
When
installing the unit at a high level, be sure to secure the unit legs.
+
Where
it is at least 3 m (9.84 ft) away from the antenna of TV set or
radio. Operation of the air conditioner may interfere with radio or TV re-
ception in areas where reception is weak. An amplifier may be required
for the affected device.
+
Install the unit horizontally.
+
Please
install it in an area not affected
by snowfall or blowing
snow.
In areas with heavy snow,
please install a canopy,
a pedestal and/or
some baffle boards.
Note:
Itis advisable to make a piping loop near outdoor unit so as to reduce
vibration transmitted from there.
Note:
When
operating the air conditioner in low outside temperature, be sure
to follow the instructions described below.
+
Never install the outdoor unit in a place where its air inlet/outlet side
may be exposed directly to wind.
+
To prevent exposure to wind, install the outdoor unit with its air inlet
side facing the wall.
+
To prevent exposure to wind,
it is recommended
to install a baffle
board on the air outlet side of the outdoor unit.
Avoid the following places for installation where air conditioner trouble
is liable to occur.
+
Where flammable gas could leak.
+
Where there is much machine oil.
+
Salty places such as the seaside.
+
Where sulfide gas is generated such as a hot spring.
+
Where there is high-frequency or wireless equipment.
FREE SPACE REQUIRED AROUND OUTDOOR UNIT
1. Top side obstacles
2. Front (blowing) side open
When there is an obstacle behind the
100 (3.94) or more
As long as space like the one
rear side only, it does not matter if
shown in the figure can be
there is an obstacle over the top side
maintained, it does not mat-
200 (7.87)
as shown in the figure below.
500 (19.68) | |
ter if there are obstacles in
YZ
SEMONe
ormore
three directions (but top side
_
4
is open).
C___)
100 (3.94)
350 (13.78)
WY
or more
or more
TH
T
t
3. Obstacles on front (blowing) side only —————————_
4, Obstacles on front and rear side only
In this case, the rear, both sides and
The unit can be used by at-
top should be open.
taching an optional outdoor
LLLLLLLLLE NEEL
+ 100 (3.94)
blowing guide (MAC-855SG)
or more
(but both sides and top are
'ge
| 500 (19.68) or more
open).
500 (19.68) or more
7,
Blowing guide (MAC-855SG)
5. Service space
Keep the service space as shown in the figure below for mainte-
.
nance.
When
installing the unit in an area that is enclosed on four sides such
as a verandah,
be sure to leave move than 200 mm
(7.87 in.) behind
the unit as shown.
+
When
there is a lack of airflow or there is a possibility of becoming
100 (3.94)
short cycle,
install an outlet guide and
make
sure there is enough
or more
space behind the rear side of the air inlet.
Service space
Note:
—-
Make sure not to install several outdoor units sideways next to each
500 (19.68) or more
other.
100 (3.94)
|
Window
or more
ULL
(LLL
if
More than 200
500 (19.68)
350 (13.78) or more
More than -
(787)
¢ More than
or more
100 (3.94)
More than
4y
350 (13.78)
VA
200 (7.87)
f
More than
200 (7.87)
Less than 1,200 (47.3) of the front surface side
[Unit: mm (inch)]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxz-4a36na

Table of Contents