The "Expert" menu

Tank ref height

Navigation
Description
User entry
Factory setting
Additional information

Tank level

Navigation
Description
Additional information

Set level

Navigation
Description
User entry
Factory setting
Additional information

Upper I/F level

Navigation
Description
174
 Expert → Application → Tank config → Level → Tank ref height (14603)
Distance from dipping ref. point to datum plate.
0 to 100 000 mm
Dependent on the device version
Read access
Write access
Expert → Application → Tank config → Level → Tank level (14655)
Shows distance from zero to product surface.
Read access
Write access
Expert → Application → Tank config → Level → Set level (14604)
Enter level obtained by manual dip.
0 to 100 000 mm
0 mm
Read access
Write access
The device adjusts the Empty parameter (→  173) according to the entered value, such
that the measured level will match the actual level.
 Expert → Application → Tank config → Level → Upper I/F level (15003)
Up I/F Level measured from zero position.