Download Print this page
Sealey AK4013 Quick Start Manual
Sealey AK4013 Quick Start Manual

Sealey AK4013 Quick Start Manual

3-60v integrated test light/voltmeter

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAFETY
WARNING! DO NOT use test light with domestic 110-230Volt supplies. Only use with DC Voltages between 3 and 60Volts.
Observe standard workshop safety procedures when using the meter.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting. Keep tools and other items away from the engine and
9
ensure you can see the working parts of the engine clearly.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.
9
Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery. Contain or tie back long hair.
9
Ensure extension leads and probes are kept clear of hot surfaces and rotating parts.
9
DO NOT drape cables around neck or arms – danger of entanglement.
8
DO NOT disassemble meter.
8
DO NOT get test light wet or use in damp or wet locations or areas where there is condensation.
8
DO NOT use the meter for any purpose other than for which it is designed.
8
DO NOT use the meter if damaged.
8
When not in use, store tester in a safe, dry, childproof location.
9
2. INTRODUCTION
Identifies the polarity of the circuit being tested on the LCD, red for positive and green for negative. Wire hook probe design, makes piercing wire
insulation easier, the hook can be locked out of the way when probing terminals. LCD meter draws minute currents making this tool safe around
delicate electronic components. With a range of 3-60V DC, this tool is suitable for motorcycle, car, mild hybrid and commercial vehicles. Supplied
with 3m coiled cable and insulated crocodile earth clamp. Do not use on airbags. Battery 1 x CR2032 (supplied).
3. SPECIFICATION
Model No.:................................................................ AK4013
Accuracy: ............................................................ ±(1%+0.3V)
Computer Safe: ..................................Testing current < 10mA
Range: .......................................................... 03-60V
4. OPERATION
4.1.
VOLTAGE MEASUREMENT
4.1.1.
Push down the hook and rotate it clockwise to expose the testing probe.
4.1.2.
Contact the probe to the 3 ~ 60V DC voltage source.
4.1.3.
Connect the test probe to positive and clip to the negative of the test object or circuit. The voltage value and "+" will be displayed on
the LCD with a "Red" background when the circuit is live.
4.1.4.
Connect the test probe to negative and clip to the positive of the test object or circuit. The voltage value and "-" will be displayed on
LCD with "Green" background when the circuit is live.
NOTE:
If user removes the probe away from the voltage source, the measured value will be held on the LCD about 3 seconds.
© Jack Sealey Limited
3-60V INTEGRATED TEST LIGHT/VOLTMETER
AK4013
MODEL NO:
DC
Fig.1
Original Language Version
Fig.2
The hook can be used to
select and pull the wire
out from multiple wires
safely.
AK4013
Issue 2 (2,3,4)
28/04/23

Advertisement

loading

Summary of Contents for Sealey AK4013

  • Page 1 AK4013 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 BATTERY REMOVAL Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.