Oil hose end meter digital

Advertisement

Quick Links

thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instruction
gloves
manual
1. saFetY
Warning! ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this
equipment.
Familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.
9
the pump station in good condition (use an authorised service agent).
Replace or repair damaged parts. Use genuine parts only. non authorised parts will invalidate the warranty.
9
Use only to pump oils up to SAe 150 viscosity.
9
ensure safety eye protection and protective clothing are worn when using this product.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
After use, drain any fluids from the equipment before storage.
9
dispose of waste liquids in accordance with local authority regulations.
9
do not exceed the maximum pressure of 750psi.
8
do not point the nozzle at people or animals.
8
do not use the equipment near open flames.
8
do not smoke whilst using this equipment.
8
do not use to extract corrosive fluids.
8
do not dismantle, tamper with or adapt the equipment for any purpose other than for which it is designed.
8
do not use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.
8
Keep the pump clean and store in a safe dry, childproof location.
9
Warning! do not allow uncontrolled discharge of fluids thus polluting the environment. All liquids must be disposed of according to
local authority regulations.
2.
introduction
i
Robust oil dispensing gun incorporating digital meter, manual shut off and tough rubber protection guard. Fitted with flexible extension
and non-drip nozzle. Easy to read 5-digit LCD display with resettable individual or cumulative totals.
3.
speciFication
i
model no: ...............................................................AK4565d
maximum Flow Rate: ............................................... 35ltr/min
Accuracy: ..................................................................... ±0.5%
Inlet Size: ..................................................................1/2"BSP
Battery .......................................... Lithium CR2 3V 1400mAh
4. assemblY
4.1.
Remove the blanking plug from the outlet end of the meter. Ensure that the threads on the nozzle pipe assembly are clean and apply
some liquid thread sealant onto the male connection. Screw both parts together and tighten.
note: do not apply too much thread sealant and ensure that none gets into the meter.
4.2.
Remove the blanking plug from the handle end and connect to the male end of the supply hose.
Warning! do not overtighten as this may cause damage to the swivel connection.
Warning! ensure that the system pressure does not exceed the 750psi of the digital meter.
© Jack Sealey limited
oil hose end meter digital
model no:
Wear eye
Wear protective
protection
clothing
Original Language Version
ak4565d
AK4565 Issue 2 (H, 5, 6, F) 24/05/18

Advertisement

loading

Summary of Contents for Sealey ak4565D

  • Page 1 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Qty dispensed fig.6 x current correction Factor = new correction Factor. Qty indicated 5.4. altering correction Factor directlY 5.4.1. Wait for meter to go to standby (fig.7). 5.4.2. Reset total (5.2.4) fig.8 to zero. fig.7 fig.8 © Jack Sealey limited Original Language Version AK4565 Issue 2 (H, 5, 6, F) 24/05/18...
  • Page 3: Changing The Battery

    Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. sealey group, kempson Way, suffolk business park, bury st edmunds, suffolk. ip32 7ar 01284 757500 01284 703534 sales@sealey.co.uk...