11.2 Re-pairing receiver and transmitter

Re-pair the receiver and transmitter if the receiver does not respond to transmitter input any longer.
Live high voltage components inside
Risk of death by electric shock
● Use insulated tools to reach controls
● Do not touch electrical components
Procedure:
No. 2832827 / 2832829
B
1. On the transmitter, push the emergency stop button (A).
2. Switch off the power supply to the receiver.
3. Remove the cover of the receiver. Make sure you do not accidentally drop screws inside the receiver.
4. Switch on the power supply to the receiver.
5. Inside the receiver, use an insulated tool and hold down the pairing button (B) until the indicator lights inside the
receiver flash RED and GREEN alternately.
à
The receiver is in pairing mode.
6. On the transmitter, push the top row buttons (C) alternatively four times (4x) to enter pairing mode.
à
The pairing indicator lights (D) flash RED and GREEN alternately.
7. Hold down the button START (E) until the pairing indicator lights (D) go out.
à
You have paired receiver and transmitter.
WARNING
No. 2832830 / 2832831
B
A
E
D
C