2) Remove all ice from the Evaporator and the Storage Bin.
Note: To remove cubes on the Evaporator, turn off the power supply and turn it
on after 3 minutes. The defrost cycle starts and the cubes will be re-
moved from the Evaporator.
3) Turn off the power supply.
4) Remove the Front Panel and then remove the Insulation Panel, by lifting the panel
slightly and pulling it toward you.
5) Remove the Base Cover.
6) Drain the Water Tank by removing one end of the Pump Tubing. See Fig. 3.
7) Refit the pump tubing in its correct position.
8) Pour the cleaning solution into the Water Tank.
9) Move the Control Switch, on the Control Box, to the "WASH" position.
10) Refit the Insulation Panel and the Front Panel in their correct positions.
11) Turn on the power supply, and start the washing process.
12) Turn off the power supply after 30 minutes.
13) Remove the Front Panel and the Insulation Panel.
14) Drain the Water Tank. (See the above step 6).
15) Refit the pump tubing in its correct position.
16) Move the Control Switch to the "ICE" position.
17) Refit the Front Panel in its correct position.
18) Turn on the power supply to fill the Water Tank with water.
19) Turn off the power supply after 3 minutes.
20) Remove the Front Panel.
21) Move the Control Switch to the "Wash" position.
22) Refit the Front Panel in its correct position.