NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
Summary of Contents for Mars Air Systems BD26 Series
Page 1
Date Company Seal or Stamp NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
VOLTAGE CODE COLOR NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
Document No: ACC-IOM Date: 04/13/2013 ACCESSORY INSTALLATION SUPPLEMENT Door Limit and Magnetic Reed Switches 3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings.
Page 7
Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
Document No: BD-IOM Date: 08/25/20 WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate, or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with these instructions could result in personal injury and/or property damage.
Page 9
If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
Page 10
D. Check all field wired components “if supplied” are wired correctly. E. Check that the inlet air supply and the discharge air supply are free of obstructions. F. Check that all air filter(s) and/or air intake grille(s) are in place and installed properly, as originally shipped. G.
Page 11
MAINTENANCE SPECIAL APPLICATIONS Outdoor Installation WARNING For outdoor unit special consideration may be required To reduce the risk of fire, electrical shock or injury to for enclosure, motor, wheel, and other components to persons, observe the following: minimize damage caused by exposure to the outdoor A.
Document No: HT-IOM Date: 10/20/2023 HEATED PRODUCTS SUPPLEMENT NOTE Before proceeding, refer to the unit’s specific IOM Manual for safety, installation, and startup information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
Page 13
Hot Water and Steam Heated Products The transition section(s) are shipped knocked down and Hot water and steam heated products are certified only are to be field assembled and installed per their for indoor use. Low Profile 2, Standard 2, High Velocity supplemental instructions (FIG.
Page 14
TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
Page 15
TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450) Applicable Capacitor Motor...
Page 16
WARRANTY Model Number: ______________________________ Serial Number: ______________________________ Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...
Page 17
Mars WindGuard BD26-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
Page 18
Mars WindGuard BD26-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units. Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium.
Mars WindGuard BD26-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Product data and certification letter indicating percentages by weight of post- consumer and pre-consumer recycled content for products having recycled content. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
Page 20
PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
Page 21
Mars WindGuard BD26-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Electrical Characteristics: 575V AC, three-phase; 29.7 Amp full load per motor for unit 192 inches wide. Fans: Forward curved centrifugal type, double width, and double inlet design, directly driven to an electric motor.
Page 22
Mars WindGuard BD26-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC BD 26 168-1: 179 Inch (4549 mm) Wide Units: 6500 feet/min (33.0 m/s) single 20HP motor/fan assemblies. BD 26 192-1: 203 Inch (5159 mm) Wide Units: 6500 feet/min (33.0 m/s) single 20HP motor/fan assemblies.
Page 23
Mars WindGuard BD26-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Connections: Opposite end, vertical. Connections: Same end, right hand, vertical. Connections: Same end, left hand, vertical. Casing: One-piece unpainted galvanized steel, bolted to air curtain housing. Supply and return fittings on top of casing.
Page 24
Mars WindGuard BD26-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Mounting: Factory mounted on right hand side of air curtain housing. Mounting: Factory mounted on left hand side of air curtain housing. Motor Control Panels for Gas Heated Units: Recommended for all units whenever a door limit switch is used to automatically start and stop the air curtain.
Page 25
Mars WindGuard BD26-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC INSTALLATION Install air curtains in accordance with approved shop drawings and manufacturer's printed installation instructions. Install air curtains plumb, level, square, true to line, and weathertight, without warp or rack. Anchor air curtains securely in place to supports.
Page 26
Mars WindGuard BD26-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC SCHEDULES Refer to Air Curtain Schedule appended to this section. END OF SECTION 23 34 33 – 10...
Belt Drive 26 Series CSI spec (Word doc) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Need help?
Do you have a question about the BD26 Series and is the answer not in the manual?
Questions and answers