Download Print this page
Mars Air Systems BD22 Series Manual

Mars Air Systems BD22 Series Manual

Industrial air curtain submittal package

Advertisement

Quick Links

BD22 Submittal Package
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ●
www.marsair.com
© Copyright Mars Air Systems, LLC 2014
BD22 Unheated Series
Belt Drive 22
Industrial Air Curtain
Submittal Package
Submitted by:
Mars Air Systems, LLC
14716 S. Broadway
Gardena, CA 90248
P.O.#
S.Q.
Company
Print Name
Signature
Date
Company Seal or Stamp
(Electronic Signature Preferred)
NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
for previously purchased equipment.
MARS AIR SYSTEMS, LLC
GARDENA, CA
USA

Advertisement

loading
Need help?

Need help?

Do you have a question about the BD22 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mars Air Systems BD22 Series

  • Page 1 Company Seal or Stamp (Electronic Signature Preferred) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 2: Table Of Contents

    CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
  • Page 4: Copyright Mars Air Systems, Llc 2014

    10 HP Motor Unit = 75 dBA, 15 HP Motor Unit = 76 dBA, 20 HP Motor Unit = 77 dBA NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 6: Accessory Installation Supplement

    Document No: ACC-IOM Date: 04/13/2013 ACCESSORY INSTALLATION SUPPLEMENT Door Limit and Magnetic Reed Switches 3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings.
  • Page 7 Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
  • Page 8: Installation, Operation And Maintenance

    Document No: BD-IOM Date: 08/25/20 WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate, or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with these instructions could result in personal injury and/or property damage.
  • Page 9 If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
  • Page 10 D. Check all field wired components “if supplied” are wired correctly. E. Check that the inlet air supply and the discharge air supply are free of obstructions. F. Check that all air filter(s) and/or air intake grille(s) are in place and installed properly, as originally shipped. G.
  • Page 11 MAINTENANCE SPECIAL APPLICATIONS Outdoor Installation WARNING For outdoor unit special consideration may be required To reduce the risk of fire, electrical shock or injury to for enclosure, motor, wheel, and other components to persons, observe the following: minimize damage caused by exposure to the outdoor A.
  • Page 12 TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
  • Page 13 TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450) Applicable Black Motor Wire &...
  • Page 14 WARRANTY Model Number: ______________________________ Serial Number: ______________________________ Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...
  • Page 15 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
  • Page 16 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units. Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium.
  • Page 17: Troubleshooting Guide

    Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Product data and certification letter indicating percentages by weight of post- consumer and pre-consumer recycled content for products having recycled content. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
  • Page 18 PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
  • Page 19 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Housing: Self-contained one-piece type with sufficient strength for mounting from pre- punched mounting holes at both ends to adjacent walls or ceiling without intermediate support. Size: Unheated: 36 inches deep by 28 inches high by width of unit.
  • Page 20 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Air Inlet Grille and Filters: Location: Front. Type: Fixed air intake grille. Expanded Metal: 85% open area. Type: Filter Only as follows: Filter: Flat bank 2-inch, disposable. Filter: V-bank 2-inch disposable.
  • Page 21 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Gas Heaters: Provide field mounted indirect natural gas fired, power vented duct furnace, with aluminized steel heat exchanger and die-formed stainless steel insert burners; manifolds, orifices, flame sensor, and igniter easily removable as an assembly.
  • Page 22 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Motor Control Panels for Gas Heated Units: Recommended for all units whenever a door limit switch is used to automatically start and stop the air curtain. Thermostat is included with optional motor control panel for field installation. Provide motor control panel as follows: Thermostat: Wall-mounted, 24-Volt operation, with heater on/off selection.
  • Page 23 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC INSTALLATION Install air curtains in accordance with approved shop drawings and manufacturer's printed installation instructions. Install air curtains plumb, level, square, true to line, and weathertight, without warp or rack. Anchor air curtains securely in place to supports.
  • Page 24 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC SCHEDULES Refer to Air Curtain Schedule appended to this section. END OF SECTION 23 34 33 – 10...
  • Page 25: Reference Links

    Belt Drive 22 Series CSI spec (Word doc) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.