Koolaire STH045 8/15 Technician's Handbook page 76

Table of Contents

Advertisement

Use the following procedure and table to help
determine if a harvest valve is remaining partially open
during the freeze cycle.
1. Wait five minutes into the freeze cycle.
2. Feel the inlet of the harvest valve(s).
Feeling the harvest valve outlet or across the
harvest valve itself will not work for this
comparison.
The harvest valve outlet is on the suction side
(cool refrigerant). It may be cool enough to touch
even if the valve is leaking.
3. Feel the compressor discharge line.
The inlet of the harvest valve and the compressor
discharge line could be hot enough to burn your
hand. Just touch them momentarily.
4. Compare the temperature of the inlet of the
harvest valves to the temperature of the
compressor discharge line.
76
Important
Warning
!
Part Number STH045 8/15

Advertisement

Table of Contents
loading

Table of Contents