Teka filtoo Operating Instructions Manual

Teka filtoo Operating Instructions Manual

Hide thumbs Also See for filtoo:

Advertisement

Quick Links

Operating instructions
(Translation of the original operating instructions)
filtoo
TEKA Absaug- und Entsorgungstechnologie GmbH, Millenkamp 9, D-48653 Coesfeld,
Tel.: +49 2541-84841-0, E-Mail: info@teka.eu, www.teka.eu
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the filtoo and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Teka filtoo

  • Page 1 Operating instructions (Translation of the original operating instructions) filtoo TEKA Absaug- und Entsorgungstechnologie GmbH, Millenkamp 9, D-48653 Coesfeld, Tel.: +49 2541-84841-0, E-Mail: info@teka.eu, www.teka.eu...
  • Page 2: Table Of Contents

    Table of contents 1. General 2. Description of the system elements 2.1. Illustration of the system elements 2.2. Functionality of the system 2.3. Intended use 2.4. Residual risk 3. Safety instructions 3.1. Definition of the hazard symbols 3.2. General safety instructions 4.
  • Page 3: General

    1. General Congratulations on purchasing the product from TEKA. Our engineers ensure that our devices reflect the state of the art through continuous development. Nevertheless, misuse or misconduct can endanger your safety. Please observe the following for a successful use of the device: Only authorised and instructed personnel can carry out transport, operation, maintenance and repair of the device.
  • Page 4: Description Of The System Elements

    2. Description of the system elements 2.1. Illustration of the system elements Installation example: Z.Nr. 09482700 Pos.1 Filter housing Pos.4 Exhaust grille Pos.2 Maintenance door Pos.5 Mains cable with plug Pos.3 Suction nozzle Pos.6 Swivel castor 2.2. Functionality of the system The filter unit serves to suck off and filter polluted air (according to the intended use).
  • Page 5: Intended Use

    2.3. Intended use The device is intended for commercial use. If the device is made publicly accessible, it must never be operated unsupervised by authorized personnel, authorized by the operator. The filter unit is intended for extraction and filtration of dusts and fumes that result from thermal joining and cutting of metals.
  • Page 6: Safety Instructions

    3. Safety instructions 3.1. Definition of the hazard symbols The device is constructed according to the state of the art and the recognised safety regulations. Nevertheless, during use threats to life and limb of the user or other persons may arise. The impairment of the machine or other property are also possible.
  • Page 7: Storage, Transport And Installation Of The Device

    WARNING Dangers arising from electricity. The operator must ensure that electrical plants and equipment are only built, modified and maintained by a qualified electrician or under the direction and supervision of a qualified electrician. Do not work on components if you are not sure that these are disconnected. If necessary, disconnect the device from the electric power supply and secure it against unauthorized restarting.
  • Page 8: Commissioning

    5. Commissioning WARNING Dangers arising from a defective condition of the unit. Make sure that the measures described in this chapter are completed before the commissioning of the unit. All doors of the unit must be closed and all necessary connections must be attached before turning the unit on.
  • Page 9: Operating The System

    6. Operating the system 6.1. Explanation of the operating elements Operating elements for the device control Representa Designation Description / function tion ON-OFF-switch By means of this switch, the device is switched on and off. When the device is switched off, it is not disconnected from the power supply.
  • Page 10: Maintenance

    7. Maintenance In accordance with national regulations, the operator is obliged to carry out repeat and functional tests. Unless otherwise specified by national regulations, we recommend regular visual inspections and functional tests of the device as described in the chapter “Maintenance intervals”. You find the chapter “Maintenance intervals”...
  • Page 11: Replacing The Filter Elements

    However, please consider our recommended changing intervals. We recommend: Note the amount of operating hours every time you replace a filter. Only use TEKA spare filters. Otherwise the proper functioning of the unit is not guaranteed. ●...
  • Page 12: Dismantling / Disposal

    A recommissioning of the device must only occur if it is ensured that the system is functionally equivalent to the original state. Repairs may only be carried out by TEKA personnel or, after consultation with TEKA GmbH, by the personnel authorised by the operator.
  • Page 13: List Of Spare Parts

    Gross filter (10 pieces) 978003 Prefilter 978004 Main filter 978005 Activated carbon filter 978006 Disposal elements Article no. PE-bag for the disposal of filter elements (3 pieces) 10030257 Other parts Article no. Suction arm for filtoo, complete 978009 BA_filtoo_20230808_EN 08.08.2023...
  • Page 14: Technical Data

    11. Technical data Version 230V, 50Hz 115V, 50Hz 115V, 60Hz Supply voltage Frequency Type of current 1Ph+N+PE 1Ph+N+PE 1Ph+N+PE Engine power Current intake 13,2 13,2 Air flow volume max. m³/h 1600 1600 1600 Negative pressure max. 1800 1800 1800 Protection class IP54 ISO class Welding fume extraction class...
  • Page 15: Ec Declaration Of Conformity

    This declaration will become void if the device is exposed to modifications that are not approved by the manufacturer in written form. Authorized representative for the technical documentation: TEKA Absaug- und Entsorgungstechnologie GmbH, Millenkamp 9, D-48653 Coesfeld (Jürgen Kemper, managing director) Coesfeld, 3rd january 2023 BA_filtoo_20230808_EN 08.08.2023...
  • Page 16: Training Protocol

    13. Training protocol Designation of the device: filtoo (This form can be used by the operator to document the training of the employees. Training should be performed by authorized personnel only. Refer to the instructions in Chapter "Safety Instructions") By his signature, the employee confirms that he has been instructed regarding the following items:...
  • Page 17: Maintenance Intervals

    Nevertheless, the filters must be replaced at the latest if the signal horn is triggered off. Maintenance work must always be documented by means of a protocol. The approach of the maintenance measures is described in chapter "Maintenance". Maintenance interval Maintenance work recommended by TEKA determined by the operator Gross filter 50 operating hours Prefilter...
  • Page 18: Visual Inspection Of The Device

    14.2.1. Visual inspection of the device Visual inspection: Observation that there are no visible safety-related defects. WARNING Danger arising from the ready to operate condition of the device. Follow the procedure as described in the chapter “Set to maintenance state”. The following steps must be carried out in the course of the visual inspection: ●...