Table of contents 1. General 2. Description of the system elements 2.1. Illustration of the system elements 2.2. Functionality of the system 2.3. Intended use 3. Safety instructions 3.1. Definition of the hazard symbols 3.2. General safety instructions 4. Storage, transport and installation of the device 5.
14.2.3. Electrical test of the electrical lines and earthing connections 1. General Congratulations on purchasing the product from TEKA. Our engineers ensure that our devices reflect the state of the art through continuous development. Nevertheless, misuse or misconduct can endanger your safety. Please observe the following for a...
2. Description of the system elements 2.1. Illustration of the system elements Z.Nr. 08461705 Pos.1 Operating panel of the control Pos.9 Suction nozzle Pos.2 Filter housing Pos.10 Exhaust air nozzle Pos.3 Turbine housing Pos.11 Connection for mains cable Pos.4 Particle filter Pos.12 Connection for external control unit Pos.5...
2.2. Functionality of the system The filter unit serves to suck off and filter polluted air (according to the intended use). First of all, the coarse particles are separated in the pocket filter in the filter section of the unit. The subsequent particle filter cleans even fine smokes and dusts.
3.2. General safety instructions WARNING Dangers arising from improper use / unauthorised operations. The operator must ensure that their authorised personnel are familiar with all the safety indications in this manual in advance. The operator is responsible for ensuring that all work is carried out by authorised and qualified personnel.
5. Commissioning WARNING Dangers arising from a defective condition of the unit. Make sure that the measures described in this chapter are completed before the commissioning of the unit. All doors of the unit must be closed and all necessary connections must be attached before turning the unit on.
5.3. Connection of the vacuum pump (optional) The vacuum pump is an optional accessory of the laser. In order to integrate the pump, please observe the indications of the laser / vacuum pump manufacturer. For integration in the device, unscrew the knurled screws at the maintenance door (see chapter 2.1). Pull out the maintenance door with the plug-in plate.
6. Operating the system 6.1. Explanation of the operating elements Control functions, setting options for programs, menu navigation, error messages, etc. are described in the enclosed operating manual of the unit control. There is also an explanation of the elements of the control panel. 6.2.
7. Maintenance In accordance with national regulations, t he operator is obliged to carry out repeat and functional tests. Unless otherwise specified by national regulations, we recommend regular visual inspections and functional tests of the device as described in the chapter “Maintenance intervals”. You find the chapter “Maintenance intervals”...
● Replace the particle filter. Only use TEKA spare filters. Otherwise the proper functioning of the unit is not guaranteed. ● Push the filter pack back into the filter housing. Make sure that the filter elements are inserted in the correct order.
7.3. Replacing the activated carbon cassette The activated carbon absorbs gases and unpleasant odours. The activated carbon has to be replaced as soon as gases appear on the clean air side. However, at the latest when the main filter of the device is replaced, the activated carbon should be replaced as well.
Page 13
● Replace the activated carbon cassette. Only use TEKA spare filters. Otherwise the proper functioning of the unit is not guaranteed. ● Push the filter pack back into the filter housing. Make sure that the filter elements are inserted in the correct order.
● Loose the hose clamp (B) for mounting the nozzle (C) at the new pocket filter. Only use TEKA spare filters. Otherwise the proper functioning of the unit is not guaranteed. ● Push the new pocket filter back in the filter housing. For this pull the nozzle (C) again in the opposite nozzle, which is inside the filter housing.
8. Dismantling / Disposal Only authorised personnel may disassemble the machine. WARNING Dangers arising from electricity. Before the dismantling of the machine it has to be disconnected from the power supply and all supply lines. CAUTION Whirling up dust is possible due to the deposited dust. During all work a suitable respiratory protection and protective clothing have to be worn.
A recommissioning of the device must only occur if it is ensured that the system is functionally equivalent to the original state. Repairs may only be carried out by TEKA personnel or, after consultation with TEKA GmbH, by the personnel authorised by the operator.
10. List of spare parts Filter element Article no. Particle filter “ H13” (305x305x100) 100310002 Activated carbon cassette (305 x 305 x 300) 97055 Pocket filter “ G4” (125 x 380 x 450) 10099000303 Other parts Article no.
This declaration will become void if the device is exposed to modifications that are not approved by the manufacturer in written form. Authorized representative for the technical documentation: TEKA Absaug- und Entsorgungstechnologie GmbH, Industriestraße 13, D-46342 Velen (Jürgen Kemper, managing director) Velen, 3rd january 2020 BA_ZING_191219_EN 19.12.2019...
13. Training protocol Designation of the device : ZING (This form can be used by the operator to document the training of the employees. Training should be performed by authorized personnel only. Refer to the instructions in Chapter "Safety Instructions")
The approach of the maintenance measures is described in chapter "Maintenance". Maintenance interval Maintenance work Chapter recommended by TEKA determined by the operator The saturation of the particle filter is automatically monitored by the filter unit and thus is not subject to a maintenance interval.
Page 21
14.2.1. Visual inspection of the device Visual inspection: Observation that there are no visible safety-related defects. WARNING Danger arising from the ready to operate condition of the device. Follow the procedure as described in the chapter “Set to maintenance state”. The following steps must be carried out in the course of the visual inspection: ●...
Page 22
14.2.3. Electrical test of the electrical lines and earthing connections WARNING Danger arising from electricity. The operator is responsible for ensuring that all work on electric components is carried out by authorised and qualified personnel. The device is subject to regular electrical checks by the operator of the device, and are subject to national standards of the different countries.
Need help?
Do you have a question about the ZING and is the answer not in the manual?
Questions and answers