Panasonic AW-PH300 Operating Instructions Manual page 11

Indoor pan/tilt head
Table of Contents

Advertisement

E Before Installing
Before installing the panftilt head, be sure to make the
following settings and changes
e Setting the Mounting Direction Switches
and Setting Others in Case of Using
Contact Type Controller, RS232C
To mount the panftilt head upright, or to control the
pan/tiit head with a contact type controller or RS-232C,
make the following settings
(This is unnecessary in case of controlling a suspend-
ed pan/tilt head from a control panel )
+ Remove the cover screws from the panftilt head and
_ carefully remove the cover
(Be careful of the tally Indicator leads when removing
the cover )
e Set switches SW1, SW2, and SW3 on the front PCB as
follows
Panftilt head suspended:
Set SW1 and SW2 to the
down position
(Default)
Panttilt head upright:
Set SW1 and SW2 to the up
position
Pan/titt head controlled with control panel: Set SW3
to the down position
(Detault)
Panftilt head controlled with contact tvpe controller
with RS-232C:
Set SW3 to the up position
e Place the cover back on and fasten it with the screws
(Be careful not to get the leads caught )
-9-