Operation - Kahlenberg M-611 Installation, Operation And Maintenance Manual

Sound and light (whistle) control
Table of Contents

Advertisement

Instructions, M-611, Software Rev. R.
Connecting Multiple M-611 Units via CAN Connection:
If installing more than one M-611 unit on a vessel, the CAN connection must be utilized so the
M-611 units can communicate with each other. When installed with the CAN connection
(Terminals 37-39 per Drg. 3-6705), the "master" M-611 is connected to installed output devices
(horns, lights), while additional M-611 units are connected only to a power source, and the
"master" M-611 via the CAN connection.
Note: If CAN connection is utilized to wire only M-611s to each other, external of a properly
configured CAN bus, a 120 Ohm resistor must be wired in parallel as a jumper between
terminals 37 and 38 (CAN HIGH and CAN LOW) on each networked M-611 to provide resistance
on this circuit.

OPERATION

INITIAL FIRST TIME PROGRAMMING REQUIRED AT THE KEYPAD:
1.) Date and Time Setup:
To set date and time, press and hold the "clock" button
will display in the Date and Time LCD Display on the unit. To change the year, use the
"Dimmer" buttons
Once the year is set, the month will appear, followed by day, hour, and minute, all
changed and set with the same procedure as was done to set the year.
2.) Device Setup:
On certain vessels, some of the sound signaling devices such as aft horn, or gong may
not be installed. In those cases, the M-611 can be customized to exclude the user from
being able to select or attempt to operate those devices that do not exist. To disable a
device, simultaneously press and hold the "Horn Select" Button
the device to be disabled for ten seconds continously. The Date and Time Display will
notify the user when the device is disabled. For example, pressing the "Horn Select"
and "Gong" button
switch. To re-enable a device, the process is the same. The Date and Time Display will
notify the user when the device is re-enabled. Once the devices that are not included in
the sound signal system have been disabled, the included P546-12 and P546-10 Button
Overlays may be permanently placed over the unused switches, to eliminate them from
view on the keypad. The M-611 is now set up and ready for normal use.
and
. Press the Morse Light Select Button
simultaneously for 10 seconds will disable the "Gong"
8
Rev. 12/19/2023
for 10 seconds. The year
to set.
and the button of

Advertisement

Table of Contents
loading