Section 2 Installation; Mechanical Installation; Electrical Installation - Wavetek 182A Instruction Manual

4 mhz function generator
Hide thumbs Also See for 182A:
Table of Contents

Advertisement

2
SECTION
INSTALLATION
2.1
MECHANICAL
INSTALLATION
After
unpacking
the instrument,
visually
inspect
all
external parts
for
possible
damage
to
connectors,
sur-
face areas,
etc.
If
damage
is
discovered,
file
a
claim
with the
carrier
who
transported the
unit.
The
shipping
container
and
packing
material
should
be saved
in
case
reshipment
is
required.
2.2
ELECTRICAL INSTALLATION
2.2.1
Power
Connection
WARNING
To
preclude
injury
or
death
due
to
shock,
the
third
wire earth
ground
must
be
con-
tinuous
to the
facility
power
outlet.
Before connecting
to
the
facility
power
outlet,
examine
extension
cords, auto-
transformers,
etc.,
between
the
instru-
ment and
the
facility
power
outlet
for
a
continuous
earth
ground
path.
The
earth
ground
path
can be
identified at
the
plug
on
the
instrument
power
cord; of
the three terminals, the earth
ground
terminal
Is
the
nonmatching
shape,
usually
cylindrical.
CAUTION
To
prevent
damage
to
the
instrument,
check
for
proper
match
of
line
and
instru-
ment
voltage
and
proper fuse type
and
rating.
NOTE
Unless otherwise
specified at the time of
purchase,
this
instrument
was
shipped
from
the factory
for
operation
on
a
90
to
126 Vac
line
supply
and
with
a
1/4
amp
stow
blow
fuse.
Instruments configured
for
198
to
252 Vac have a
1/8
amp
slow blow
fuse.
Select the appropriate fuse
and
115
or
230
switch
position at
the rear
panel
when
changing
power
sources.
2.2.2
Signal
Connections
Use
3
foot
RG58U
500
shielded
cables equipped
with
female
BNC
connectors
to distribute
all
input
and
out-
put
signals.
2.3
ELECTRICAL
ACCEPTANCE CHECK
This
checkout procedure
is
a
general
verification of
generator
operation.
Should a
malfunction
be
found,
refer to
the
warranty
in
the
front of
this
manual.
A
two channel
oscilloscope, four
3
foot
500 coax
cables
with
female
BNC
connectors, a
coax
tee con-
nector
and an
additional function
generator are
re-
quired
for this
procedure.
Preset the generator
front
panel controls
as
follows:
Control
Position
Dial
2,0
MODE
CONT
(released)
FUNCTION
Oj
DCOFFSET
OFF(ccw)
AMPLITUDE
MAX(cw)
FREQUENCY
MULTIPLIER
X1K
Set
up
the oscilloscope,
Model
182A and
external
function
generator as
shown
in
figure
2-1
and
perform
the steps
in
table
2-1
VCG
IN
±dc
FUNCTION
GENERATOR
OR
VOLTAGE SOURCE
(INITIALLY
OFF)
Figure
2-1.
First
Setup
2.4
CHANGING
THE OUTPUT IMPEDANCE
The
output
impedance
is
normally:
HI
10V
p-p
(500 source)
into
500.
LO
1Vp-p
(500 source)
into
500.
Amplitude
is
normally
variable
over
30
dB
with
-
50
dB
lowest possible amplitude.
2-1