Charger Indicator - EINHELL TC-CD 18 Li Original Operating Instructions

Table of Contents

Advertisement

Available languages

Available languages

10. Charger indicator

Indicator status
Green is flashing
Red in on
Green is on
Red is flashing
Red and green are flashing
alternately
Anl_TC-CD_18_Li_GLOBUS_SPK7.indb 19
Anl_TC-CD_18_Li_GLOBUS_SPK7.indb 19
GB
Explanations and actions
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
Charging
The charger is charging the battery pack.
The battery is charged and ready for use. (READY TO GO)
(Charging time for 1.5 Ah battery: approx. 2 hours)
(Charging time for 2.0 Ah battery: approx. 2½ hours)
(Charging time for 3.0 Ah battery: approx. 4 hours)
(Charging time for 4.0 Ah battery: approx. 5 hours)
(Charging time for 5.2 Ah battery: approx. 6½ hours)
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Fault
Charging is no longer possible. The battery pack or charger is defec-
tive.
Action:
Never charge a defective battery pack.
Take the battery pack out of the charger.
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature (approx. 20°
C) for one day .
Should this fault still occur afterwards, the battery has undergone ex-
haustive discharge and must never be charged or used again. Take the
battery pack out of the charger.