Coil
Insulation
Gasket
Fig06288
9) Lift Using a couple of straps, wrap them around
the Coil and attach to a hoist to lift off. You may
also use the lifting eyes with hooks to lift with
hoist. This coil weighs at least 125 lbs. If no
hoist is available, it is recommended that this
become a 2-man job each with the ability to lift
at least 65 lbs.
10) Clean the coil.
11) Reassemble the coil and lids to the machine.
Make sure the white insulation remains in place.
12) Reattach high-pressure hose and thermostat
and make sure all fittings are tight before using
the machine.
Maintenance & Repair

Inspect/Clean/Adjust Electrodes

Inspect electrodes yearly and replace as needed.
1) Loosen front (2) bolts using a 1/2" socket. Loosen
2) Remove (3) screws using a 5/32" hex key Allen
3) Disconnect flame sensor and electrode wires.
4) Clean off carbon deposits, which may have
5) If electrodes are outside of manufacturing
NOTICE:
every 100 hours. If the flame sensor lens gets sooted up
the flame sensor will be unable to sense a flame and
therefore the burner will not fire. Do not contamminate
or touch the fuel nozzle tip.
29
side (2) bolts using a 1/2" socket and wrench.
wrench from the combustion head. Lift off
combustion head from outer cover.
Fig06842
Disconnect fuel line.
accumulated on the tips of the electrodes.
specification, Replace electrodes.
ITEM#
A
1574212
.188
Wipe combustion head flame sensor lens
Fig06843
Label dimension
B
C
.188
.109