Huawei SUN2000-10KTL-BEM1 Quick Manual page 6

Hide thumbs Also See for SUN2000-10KTL-BEM1:
Table of Contents

Advertisement

No. Item
9
AC switch
3.2
Installing the PE Cable
Do not connect the neutral wire to the enclosure as a PE cable. Otherwise, electric shocks may
occur.
The PE point at the AC output port is used only as a PE equipotential point, and cannot
substitute for the PE point on the enclosure.
It is recommended that silica gel or paint be used around the ground terminal after the PE
cable is connected.
3.3
Installing the AC Output Power Cable
Ensure that the protection layer of the AC output power cable is inside the connector, the core
wires are totally inserted into the cable hole, and the cable is connected securely. Failing to do
so may cause device malfunction or damage.
1. Connect the AC output power cable to the AC connector.
Stripping Requirements
Type
Recommended: three-
phase AC circuit
breaker
Specifications
Rated voltage ≥ 380 V AC
Rated current:
16 A (3KTL–6KTL)
25 A (8KTL–10KTL)
5