Pressure Relief Procedure; Cleanup - Titan Tool SPEEFLO PowrTwin 6900 DI Plus Owner's Manual

Table of Contents

Advertisement

7. Turn the pressure control knob clockwise approximately
1/3 of the way down to increase pressure until the sprayer
cycles evenly and paint flows freely from the bleed hose.
8. Turn off the sprayer.
a.
To turn off the gas engine,
set the pressure to minimum by turning the pressure
control knob fully counterclockwise,
move the throttle lever to the slow position, and
turn the engine switch to the OFF position.
b.
To turn off the electric motor,
set the pressure to minimum by turning the pressure
control knob fully counterclockwise,
move the ON/OFF switch to the OFF position.
9. Remove the bleed hose from the waste container and
place it into the container of paint.
10. Close the bleed valve by rotating the bleed valve handle
fully clockwise.
11. Start the engine or turn on the electric motor.
12. Turn the pressure control knob clockwise approximately
1/3 of the way down to increase pressure.
13. Unlock the gun by turning the gun trigger lock to the
unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.
14. Trigger the gun into the metal waste container until all air
and solvent is flushed from the spray hose and paint is
flowing freely. from the gun.
1 5. Lock the gun by turning the gun trigger
lock to the locked position.
16. Turn off the sprayer.
17. Attach tip guard and tip to the gun as
instructed by the tip guard or tip manuals.
POSSIBLE INJEcTION haZaRD. Do not spray
without the tip guard in place. Never trigger the
gun unless the tip is in either the spray or the
unclog position. always engage the gun trigger
lock before removing, replacing or cleaning tip.
18. Start the engine or turn on the electric motor.
19. Increase the pressure by turning the pressure control knob
slowly clockwise and test the spray pattern on a piece
of cardboard. Adjust the pressure control knob until the
spray from the gun is completely atomized.
NOTE: Turning the pressure up higher then needed to
atomize the paint will cause premature tip wear
and additional overspray.
© Titan Tool Inc. All rights reserved.

Pressure Relief Procedure

1. Lock the gun by turning the gun trigger
2. Turn off the sprayer.
a.
b.
3. Close the hydraulic shut-off valve on the hydraulic
4. Unlock the gun by turning the gun trigger lock to the
5. Hold the metal part of the gun firmly to the
6. Trigger the gun to remove any pressure
7. Lock the gun by turning the gun trigger lock to the locked
8. Place the bleed hose into the metal waste container.
9. Open the bleed valve by rotating the bleed valve handle
Trigger lock in
locked position.

cleanup

• Always flush spray gun preferably outside and at least one
• If collecting flushed solvents in a one gallon metal
• Area must be free of flammable vapors.
• Follow all cleanup instructions.
IMPORTaNT: The sprayer, hose, and gun should be cleaned
thoroughly after daily use. Failure to do so permits material
to build up, seriously affecting the performance of the unit.
1. Follow the "Pressure Relief Procedure" found in the
2. Remove the gun tip and tip guard and clean with a brush
3. Place the siphon tube into a container of the appropriate
IMPORTaNT: use only compatible solvents when cleaning
out oil based enamels, lacquers, coal tar, and epoxies.
check with the fluid manufacturer for the recommended
solvent.
9
Be sure to follow the Pressure Relief Procedure
when shutting the unit down for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray nozzles,
or preparing for cleanup.
lock to the locked position.
To turn off the gas engine,
set the pressure to minimum by
turning the pressure control knob fully
counterclockwise,
move the throttle lever to the slow
position, and
turn the engine switch to the OFF position.
To turn off the electric motor,
set the pressure to minimum by turning the pressure
control knob fully counterclockwise,
move the ON/OFF switch to the OFF position.
pressure hose.
unlocked position.
side of a metal waste container to ground
the gun and avoid a build up of static
electricity.
that may still be in the hose.
position.
fully counterclockwise.
Special cleanup instructions for use with
flammable solvents:
hose length from spray pump.
container, place it into an empty five gallon container, then
flush solvents.
always spray at minimum pressure with the gun
nozzle tip removed when using mineral spirits or
any other solvent to clean the sprayer, hose, or
gun. Static electricity buildup may result in a fire
or explosion in the presence of flammable vapors.
Operation section of this manual.
using the appropriate solvent.
solvent.
Trigger lock in
locked position.

Advertisement

Table of Contents
loading

Table of Contents