Energenics UV-MAX Installation & Operation Manual

Energenics UV-MAX Installation & Operation Manual

Mobile disinfection system

Advertisement

Quick Links

________________________________________________________________________________________________________________
1470 Don Street ∙ Naples, Florida 34104
Installation & Operations Manual for Energenics UV-MAX

Table of Contents

Advisories (Purpose/Contents)
Operation Settings (Customizable)
FAQ
®
CORPORATION
Mobile Disinfection System
Telephone
1
www.energenics.com
(239) 643-1711
Customer Service
(800) 944-1711
Fax
(239) 643-6081
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13
Pages 14-15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UV-MAX and is the answer not in the manual?

Questions and answers

Summary of Contents for Energenics UV-MAX

  • Page 1: Table Of Contents

    ________________________________________________________________________________________________________________ 1470 Don Street ∙ Naples, Florida 34104 Telephone (239) 643-1711 Customer Service (800) 944-1711 (239) 643-6081 Installation & Operations Manual for Energenics UV-MAX Mobile Disinfection System Table of Contents Page 1 Energenics UV-MAX Page 2 Advisories (Purpose/Contents) Page 3...
  • Page 3: Energenics Uv-Max

    Advisories Purpose The Energenics UV-MAX system has been designed to offer direct disinfection exposure to surface areas. The system design allows for microbial disinfection control. The Energenics UV-MAX system was developed as a disinfection tool, utilizing Ultraviolet Light (UV) for direct exposure disinfection. The system can disinfect 360 degrees from the system center.
  • Page 4: Uv-Max Safe Operation Procedure

    UV-MAX Safe Operation Procedure 1. Always wear personal protective equipment (PPE) when operating UV-MAX to limit exposure to light 2. Place UV-MAX in area to be treated 3. Ensure the PIR Sensors (Passive Infrared) are positioned to the re-entry point. PIR sensors operations are explained in the FAQ section at the end of this manual.
  • Page 5: Safety Guidelines

    Unfortunately, there are no immediate warning symptoms to indicate overexposure to UV radiation and adverse effects typically appear hours after exposure has occurred. The Energenics UV-MAX is designed for zero user exposure to UV-C; however, we will review safety factors regarding UV-C for better knowledge and understanding.
  • Page 6: System Description

    System Description The Energenics UV-MAX is designed for maximum disinfection through the shortest exposure time. More UV-C wattage allows shorter exposure times to surfaces. Exposure times vary based on furthest distance from the UV-C source. The system design provides the optimum in:...
  • Page 7: System Delivery

    System Delivery When you receive your UV-MAX, you will need to unpack and inspect the system. Please perform the following procedure: 1. Unpack your new system and stand upright 2. Inspect fully for damage If damage present, contact Energenics prior to use (800) 944-1711 3.
  • Page 8: Operation Overview

    Operation Overview The UV-MAX is designed to operate in the following manner: Start Sequence 1. Locate unit in unoccupied space positioned for operation 2. Plug system into power supply 3. Press on-screen logo to display “Start Cycle” state 4. Initiate system cycle 5.
  • Page 9: Operation Settings (Default)

    Operation Settings Normal operation for factory default settings are covered on this page. 1. Review system for condition. a. There should be no physical damage to the system b. Lamps shall be clean c. System frame shall be in good condition d.
  • Page 10 Customizable Operation Settings Customizing settings for normal operation are covered on this page. 1. From the START CYCLE home screen, press USER SETTINGS button 2. The COUNTDOWN TIMER / CYCLE TIMER screen is displayed and may be used to modify system variables as follows: Countdown Timer–...
  • Page 11: Cycle Stop Status Screens

    Cycle Stop Status Screens Cycle stop displays for normal system operation are covered on this page. Emergency Stop Should cycle deactivation occur by engagement of the Emergency Stop button, the following method will be required to reset the system: 1. Observe Emergency Stop Active status on control screen 2.
  • Page 12: System Care

    System Care The Energenics UV-MAX system is designed for repeat performance and consistent results. Based on system designs, minimal maintenance is required. Adherence to the following regular service of your system should provide years of disinfection. Each Duty Cycle 1. Inspect the system interior, exterior, and lamps for clean conditions 2.
  • Page 13: Troubleshooting

    A: Verify the display is reads correctly A: Verify the Emergency Stop is not engaged A: Contact Energenics Support for further information Q: Why does the unit turn off when I enter the room? A: Safety features turn off lamps based on detection by the PIR sensor.
  • Page 14 FAQ (continued) Q: What is a PIR (Passive Infrared) Sensor? A: Passive InfraRed sensors (PIRs) are electronic devices which are used in some security alarm systems to detect motion of an infrared emitting source, usually a human body. Q: Is UV-C disinfection strictly line of sight? A: Yes, it needs to shine on the surface to disinfect.
  • Page 15 FAQ (continued) Q: How can I test if UV is disinfecting my surfaces? A: Confirmation of efficacy can be made through adenosine triphosphate (ATP) testing or by sending test samples to a third-party laboratory. ATP is the energy molecule found in all living and once-living things, making it a good indicator when trying to determine if a surface is clean or not.
  • Page 16 In no event shall Energenics be liable for any consequential, incidental or special damages of any kind caused by the defect. The Warranty set forth shall not apply to & Energenics shall not be responsible for any equipment or part, which has been repaired or altered in any way,...