Energenics MAX-ASSURE UV-MAX ULTRA Installation & Operation Manual

Energenics MAX-ASSURE UV-MAX ULTRA Installation & Operation Manual

Mobile surface disinfection unit

Advertisement

Quick Links

________________________________________________________________________________________________________________
1470 Don Street ∙ Naples, Florida 34104
UV-MAX ULTRA Mobile Surface Disinfection Unit
Table of Contents.................................................................................1
Advisories (Purpose/Contents)............................................................... 2
UV-MAX Safe Operation Procedure.........................................................3
Safety Guidelines................................................................................ 4
System Description..............................................................................5
System Delivery...................................................................................6
Operation Overview..............................................................................7
Operation Settings (Default)...................................................................8
Operation Settings (Customizable)..........................................................9
Room Sensing...................................................................................10
E-Stop / System Interruptions................................................................11
Alerts / Service Indicators / Alarms.........................................................12-13
System Care......................................................................................14
Troubleshooting..................................................................................15
FAQ.................................................................................................16-17
Installation & Operations Manual
1
www.max-assure.com
Telephone
(239) 643-2778
Customer Service
(800) 944-1711
Fax
(239) 643-6081

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAX-ASSURE UV-MAX ULTRA and is the answer not in the manual?

Questions and answers

Summary of Contents for Energenics MAX-ASSURE UV-MAX ULTRA

  • Page 1: Table Of Contents

    www.max-assure.com ________________________________________________________________________________________________________________ 1470 Don Street ∙ Naples, Florida 34104 Telephone (239) 643-2778 Customer Service (800) 944-1711 (239) 643-6081 Installation & Operations Manual UV-MAX ULTRA Mobile Surface Disinfection Unit Table of Contents……………………………………………………………………...1 Advisories (Purpose/Contents)……………………………………………………... 2 UV-MAX Safe Operation Procedure………………………………………………...3 Safety Guidelines…………………………………………………………………….. 4 System Description……………………………………………………………………5 System Delivery………………………………………………………………………..6 Operation Overview……………………………………………………...……………7...
  • Page 2: Advisories (Purpose/Contents)

    The Energenics UV-MAX ULTRA system has been designed to offer direct disinfection exposure to surface areas. The system design allows for microbial disinfection control. The Energenics UV-MAX ULTRA device was developed utilizing Ultraviolet Light (UV) for direct exposure disinfection. The system can disinfect 360 degrees from the system center.
  • Page 3: Uv-Max Safe Operation Procedure

    UV-MAX Safe Operation Procedure 1. Always wear personal protective equipment (PPE) when operating UV-MAX ULTRA to limit exposure to UV-C light 2. Place UV-MAX ULTRA in area to be treated 3. Ensure a PIR Sensor (Passive Infrared) is positioned toward the entryway. PIR sensors operations are explained in the FAQ section at the end of this manual.
  • Page 4: Safety Guidelines

    Safety Guidelines Long term exposure to ultraviolet light is dangerous. UV-C can produce eye injuries and skin irritation similar to a sun burn over prolonged exposure. These effects are considered transient. UV-C may also be carcinogenic but since it has very limited penetrating ability it is unlikely to cause damage to anything besides the outer layer of skin or other exposed surfaces.
  • Page 5: System Description

    System Description The UV-MAX ULTRA is designed for maximum disinfection through the shortest exposure time. More UV-C wattage allows shorter surface exposure times. Exposure times vary based on furthest distance from the UV-C source. The system design provides the optimum in: o UV dosage output to footprint served o Rugged design build o Ease of use controls...
  • Page 6: System Delivery

    System Delivery When you receive your UV-MAX ULTRA, you will need to unpack and inspect the system. Please perform the following procedure: 1. Unpack your new system and stand upright 2. Inspect fully for damage If damage present, contact MaxAssure, Inc prior to use (239) 643-2778 3.
  • Page 7: Operation Overview

    Operation Overview The UV-MAX is designed to operate in the following manner: Start Sequence 1. Locate unit in unoccupied space positioned for operation 2. Plug system into power supply 3. Press “Bacteria” or “Spores” Operation Mode 4. Initiate system cycle by pressing “Start Cycle” 5.
  • Page 8: Operation Settings (Default)

    Operation Settings Normal operation for factory default settings are covered on this page. 1. Review system for condition. a. There should be no physical damage to the system b. Lamps shall be clean c. System frame shall be in good condition d.
  • Page 9: Operation Settings (Customizable)

    Customizable Operation Settings Customizing settings for normal operation are covered on this page. Target Pathogen Selection Options 1. From Start Cycle home screen, user may select either “Bacteria” or “Spores” Operation Mode (System default is Bacteria Mode) 2. Selection may also be made by selecting “User Settings”...
  • Page 10: Room Sensing

    Status Screens Room Sensing Technology covered on this page. Room Sensing Feature The UV-MAX ULTRA is equipped with Room Sensing Technology in which the device will calculate the distance between walls and calculate the required machine run-time depending on Operation Mode (Bacteria or Spores) selected. 1.
  • Page 11: E-Stop / System Interruptions

    Status Screens Cycle stop displays for normal system operation are covered on this page. Emergency Stop Should cycle deactivation occur by engagement of the Emergency Stop button, the following method will be required to reset the system: 1. Observe Emergency Stop Active status on control screen 2.
  • Page 12: Alerts / Service Indicators / Alarms

    Status Screens System lamp faults and service indicators are covered on this page. Alerts A Service or Alarm indicator may be illuminated on the Home screen. Should this occur, the following steps should be taken to address the alert: 1. Observe the alert type on the control panel 2.
  • Page 13 Status Screens (con’t) g. Press “Home” to return to Start Cycle screen Lamps are designed for 12,000 run hours after which point, they will only provide 80% of original UVC dosage output and will continue to degrade. The device will alert for lamp replacement at 8,000 run hours.
  • Page 14: System Care

    System Care The UV-MAX ULTRA system is designed for repeat performance with consistent results. Based on system designs, minimal maintenance is required. Adherence to the following regular service of your system should provide years of disinfection. Each Duty Cycle 1. Inspect the system interior, exterior, and lamps for clean conditions 2.
  • Page 15: Troubleshooting

    A: Verify the start cycle button is pressed A: Inspect the lamp for age or physical failure A: Contact Energenics Support for further information Q: My system is running fine, how do I verify the lamp output is correct? A: The system has a status screen at the end of the cycle A: Faults will indicate if the system is not performing correctly Q: The touchscreen has presented a flashing “Service Machine”...
  • Page 16: Faq

    FAQ (continued) Q: What is a PIR (Passive Infrared) Sensor? A: Passive InfraRed sensors (PIRs) are electronic devices which are used in some security alarm systems to detect motion of an infrared emitting source, usually a human body. Radiation (energy) is invisible to the human eye but can be detected by electronic devices designed for such a purpose.
  • Page 17 FAQ (continued) Q: Does UV-C light go through glass or windows? A: Standard window glass blocks almost 100% of UV-C light according to the IUVA. (Normal glass, as used in a window, is transparent to UV radiation to a wavelength of about 330 nm (UV-A).

Table of Contents