Summary of Contents for Laser Technology TruPulse L2
Page 1
TruPulse ® User’s Manual 1.303.649.1000 ServiceCenter@LaserTech.com 6912 S. Quentin St, Suite A Centennial, CO 80112 @LaserTechnologyInc @LaserTechnologyInc @LaserTechInc_ @LaserTechPro @Laser-Technology...
Page 2
Information in this document is subject to change without notice and does not represent a commitment on the part of Laser Technology, Inc. No part of this manual may be reproduced in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose other than the purchaser’s...
Laser Technology, Inc. TruPulse L2 User’s Manual 1st Edition Introduction Page 2 Introduction • The safety instructions and the user manual should be read through carefully before the product is used for the first time. • The person responsible for the product must ensure that all users understand these directions and adhere to them.
3-Point Height Routine Filter 2D Missing Line Routine Unpacking the TruPulse L2 When you unpack the TruPulse L2, check to make sure that you received everything that you ordered, and that it all arrived undamaged. Basic Package: • TruPulse L2 •...
The laser may be active for a maximum of 10 seconds. Once the target is acquired or the laser has timed out, you can release the FIRE button. The TruPulse L2 has a broad spectrum of sensitivity and can work with both reflective and non-reflective targets.
H. Down Arrow Button L. Battery CR2 Figure 1 Battery Your TruPulse L2 rangefinder comes with a battery already installed. Before Using: Open the battery door by releasing the latch and pushing the door down (Figure 2A). NOTE The CR2 battery is already in place.
Page 7 Section 3 - Basic Measurement Press FIRE button to power ON the TruPulse L2. Select a target such as a tree or a building. Look through the eyepiece and use the crosshair to aim to the target. Press-and-hold the fire button. The Laser indicator is displayed while the laser is active measuring.
Button Navigation The TruPulse L2 has four buttons. With the TruPulse L2 in your right hand and looking through the eyepiece, the fire button is located on top, near your index finger The Navigation and Up/Down buttons and are located on the left side of the instrument.
TruPulse L2 Display The TruPulse L2 is equipped dual color display and can show information in Red or black. With a built-in light sensor that reads ambient light. The internal software adjusts the red brightness intensity based on the measured light reading.
The unit continuously acquires targets and displays measurements Mode while the FIRE button is held down. Inclination The angle of inclination between the TruPulse L2 at level and the target. Measurement Slope Distance Straight line distance between the TruPulse L2 and the target.
In Figure 9, F-06.0 is used as an example. Release the FIRE button to start normal operation. Factory Reset It is possible to restore the TruPulse L2 factory default settings. Figure 9 Restoring the default settings affects some of the system setup options.
Laser Technology, Inc. TruPulse L2 User’s Manual 1st Edition Section 4 - Basic Operations Page 12 Neck Strap To attach the neck strap: Disconnect the anchor end of the strap using the buckle. Feed loop around metal bar. Thread the neckstrap through the loop.
Section 5 - Measurement Modes When you power ON the TruPulse L2, the last used Measurement Mode will be active. Press the Up or Down arrow to display other Measurement Modes. Figure 12 shows the four different types of measurements that the TruPulse L2 can take.
Laser Technology, Inc. TruPulse L2 User’s Manual 1st Edition Section 5 - Measurement Modes Page 14 Distance and Inclination Measurements Workflow Figure 13 Inclination Percent Slope Percent slope, indicated by the % indicator, is a calculation equal to 100 times the tangent of the inclination angle.
Height Measurements involve a simple routine that prompts you to take 3 shots to the target: Horizontal Distance, Inclination Angle_1 and Inclination Angle_2. The TruPulse L2 uses these results to calculate the height of the target. In the routine, the next measurement required will auto sequence once the first measurement is acquired.
Laser Technology, Inc. TruPulse L2 User’s Manual 1st Edition Section 5 - Measurement Modes Page 17 Height Routine (2-pt Routine) This measurement routine is ideal for leaning objects and requires a clear line of sight for both shots. Press Up or Down buttons until the Vertical Distance (VD) indicator is displayed.
The simple routine prompts you to take two shots to targets: “Shot 1" and “Shot 2". The TruPulse L2 uses the results to calculate values between the two points: slope distance, inclination, horizontal distance, and vertical distance from Shot 1 to Shot 2.
Section 6 - System Setting Menu Targeting Modes The TruPulse L2 has five Target Modes which allow you to select or eliminate targets and to take the most accurate measurements possible in various field conditions. The selected Target Mode remains active until you select a different Target Mode.
Laser Technology, Inc. TruPulse L2 User’s Manual 1st Edition Section 6 - System Setting Menu Page 22 Aiming Reticle Options Use the reticle to align over the target you would like to measure to. Choose from four reticle options: Full...
Section 6 - System Setting Menu Page 23 Units of Measurements (UoM) The TruPulse L2 allows you to choose the units of measure. Distance: meters or feet. Inclination: Degrees or % Slope. To change the units of measurement option: Press-and-hold Display/Menu button Then press Up or Down Arrow buttons to scroll until the UoM option screen is displayed.
Page 24 Pulse Settings The TruPulse L2 has a Pulse Motor to help indicate the target has been acquired. This feature provides short vibrating pulses/bursts to give a tactile confirmation and to reinforce that the laser has locked on the target.
The instrument is rated for an operating temperature range of -5° to +60º C (23° to 140° F); Storage -25 to 60 degrees C (-13° to 140° degrees F). Do not expose the TruPulse L2 to temperatures outside this range.
Laser Technology, Inc. TruPulse L2 User’s Manual 1st Edition Section 8 - Specifications Page 26 Section 8 - Specifications All specifications are subject to change without notice. Please refer to LTI's website for current specifications. I f you are not able to locate the information on the website or if you do not have internet access, please contact LTI via phone or fax.
What is Covered? Laser Technology, Inc. (LTI) warrants this product to be in good working order. Should the product fail to be in good working order at any time during the warranty period, LTI will, at its option, repair or replace this product at no additional charge.
Laser Technology, Inc. TruPulse L2 User’s Manual 1st Edition Section 10 - Main Display LCD Characters Page 28 Section 10 - Main Display LCD Characters The Main Display is used to convey messages and measurement results. Upper Main Display Lower Main Display...