AUTOMATIC OPERATION
"AUTOMATIC" operation is established by programming the time/temperature settings for specific
time, "SET-BACK" mode operation will be programmed in a 24-hour period. It is designed for energy
efficiency by using a lower temperature setting, generally at night.
Ex.
1.
Set Start Time of "SET-BACK" Mode.
A. Slide the timer selector to "START SET-BACK".
B. Press "HOUR" and "MINUTE" button of TIMER/CLOCK SET to set desired start time.
Note: When setting "SET-BACK" time, the "MINUTE" button will advance time by ten (10) units.
(Ex. 10:00, 10:10, 10:20, etc.)
C. Start time of "SET-BACK" mode will be shown on digital indicator. (Ex. PM 10:00)
2.
Set End Time of "SET-BACK" Mode.
With the timer selector slide switch in the "END SET-BACK" position, program the end time as
described above. (Ex. AM 6:00)
Important: Always return timer selector to "CLOCK/TEMP (NORMAL POSITION)" after settings.
3.
Set Room Temperature.
Slide "NORMAL" temperature selector and "SET-BACK" temperature selector at the position you
desire. (Ex. "NORMAL" - 75˚F, "SET-BACK" - 60˚F)
Note:
The temperature setting currently being used is displayed on the digital indicator. To view and
set the Set-Back temperature setting, press the "MINUTE" button for more than three (3)
seconds. The display will go back to the Normal temperature setting after ten (10) seconds.
4.
Push in AUTO switch to "ON" position.
5.
Turn Power ON.
Press ON/OFF switch to "ON" position. ON/OFF lamp will start to flash and AUTO switch lamp will light.
And then blower motor and ignition will start.
Note:
SET-BACK OPERATION IRREGULAITIES: If a heater is switched "OFF"; if the "AUTOMATIC"
operation is switched off; or there is a power interruption while the unit is operating in the
"SET-BACK" mode, the "SET-BACK" mode may be temporarily disabled until the next Start
Set-Back time.
Approx. +4˚F
Approx. +1˚F
SET
TEMP.
High
Medium
"NORMAL"
"NORMAL"
mode
60˚F
"SET-BACK"
mode
PM10:00
AM6:00
Start Set-Back
Low
Off
Re-Ignition
75˚F
mode
60˚F
PM10:00
AM6:00
End Set-Back