Sign In
Upload
Download
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Keithley Manuals
Measuring Instruments
172
Instruction manual
Keithley 172 Instruction Manual page 38
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
page
of
151
Go
/
151
Bookmarks
Advertisement
I
QPERATING
INSTRUCTIONS
INSTRUCTION
MANUAL
Digital Mullimeler
Models 172.173
I
TABLE
3-g.
General
Characteristics
of
Model
1722 Digital
Interface.
I
DIGITAL
OUTPUTS:
Logic:
BCD (8421)
Open-collector
positive
true
unless
otherwise
specified.
Data:
4 full
digits,
I partial
digit
(0,
I,
2,
3) and exponential
range
code.
1
Function:
4-bit
code
(n,
AC VOLTS,
AMPS)
1
Polarity:
HIGH : +.
Overflow:
LOW s >
23333.
:
Autorange:
LOW s range
change.
!
Automode:
HIGH s
autorange
mode.
FLAG (m):
HIGH (logic
"0"
: no output
change
occuring.
,
Logic
Levels:
HIGH f open
collector
to output
LO.
LOW 5 closure
to output
LO.
/
device
(2N5134)
greater
than
20V breakdown,
Output
<0.5V
at
5mA sink
(3TTL
loads).
Internal
pull-up
resistors
may be installed
on these
open
collector
outputs.
4.7K
minimum
value
is
recommended
when
using
internal
5
volt
power
supply.
I
.
OUTPUT TIMING:
Data
is
updated
typically
every
320 msec
(non-trigger
mode).
Update
time
is
typically
1.2
msec.
Data
will
appear
at
an output
only
if
its
respective
strobe
is
active.
The
FLAG will
go low
(Logic
"0")
typically
2 msec before
update
and
go high
typically
100 usec
after
update.
long
as the
flag
is
high.
Data
can
be expected
to be unchanging
so
If
FLAG RESET is
activated,
"0")
until
the
end ~of the
next
data
update.
the
FLAG will
reset
(go
to
Logic
REMOTE CONTROLS:
1
Strobe:
Strobe
lines
permit
word
serializing
in
4-bit
increments
or multiples
thereof.
HIGH
inhibits
controlled
output
lines
from
conduction,
LOW enables
conduction.
Range
In:
4-bit
exponential
code.
L&
Range:
Low enables
remote
ranging
as set
by Range
code.
Hold:
LOW inhibits
display
update,
conversions)
.
output
update
and autorange
(A/D
continues
(
Printer
Hold:
Same as hold
but
grouped
with
outputs
for
convenience
in
interfacing
I
printer.
Trigger
Mode:
LOW enables
TRIGGER control.
,
Trigger
Mode Disable:
LOW disables
TRIGGER.
Trigger:
LOW to HIGH transition
initiates
a new A/D
conversion.
Flag
Reset:
Low sets
FLAG (FLAG)
t0
LOW (HIGH),
I
Control
Logic
Levels
G Source
Requirements:
HIGH 3 either
an open
circuit
or
a
voltage
between
+2.4V
and
5V referred
to output
LO.
LOW : closure
to outcut
LO
within
0.8V
while
sinking
+T.6
milliamperes
(ITTL
load).
When TRIGGER MODE, HE
and
LOAD RANGE code
bits
are
all
HIGH
(inactive)
the
172/173
is
under
front
panel
I
control.
These
REMOTE CONTROL inputs
have
priority
and will
override
any
front
panel
setting
once
activated.
ISOLATION:
All
digital
outputs
and
remote
controls
are
isolated
from
172/173
analog
input
by
10'
0 and 5OOpF,
1200 VDC,
1OOOV rms AC maximum.
All
digital
outputs
and
remote
controls
are
isolated
from
chassis
ground
by
I06
R and 0.0l~F;
250V
rms
maximum.
I
1
I
AA
Previous
Page
Next
Page
1
...
35
36
37
38
39
40
41
42
Advertisement
Related Manuals for Keithley 172
Measuring Instruments Keithley 177 Instruction Manual
Microvolt dmm, battery pack (54 pages)
Measuring Instruments Keithley 1793 Instruction Manual
Ieee standard 488 output (25 pages)
Measuring Instruments Keithley 199 Quick Reference Manual
System dmm/scanner (49 pages)
Measuring Instruments Keithley 148 Instruction Manual
Nanovoltmeter (67 pages)
Measuring Instruments Keithley 196 DMM Instruction Manual
5 function autoranging digital multimeter (78 pages)
Measuring Instruments Keithley 181 Service Manual
Digital nanovoltmeter (69 pages)
Measuring Instruments Keithley 194 Instruction Manual
High speed voltmeter (281 pages)
Measuring Instruments Keithley 1920 Instruction Manual
Trms option (35 pages)
Measuring Instruments Keithley 196 Instruction Manual
System dmm (162 pages)
Measuring Instruments Keithley 182-M Quick Reference Manual
Sensitive digital voltmeter (39 pages)
Measuring Instruments Keithley 182 Quick Reference Manual
Sensitive digital voltmeter (38 pages)
Measuring Instruments Keithley 153 Instruction Manual
Microvolt-ammeter (51 pages)
Measuring Instruments Keithley 193A Instruction Manual
System dmm (183 pages)
Measuring Instruments Keithley 192 Instruction Manual
Programmable dmm and ac option (90 pages)
Measuring Instruments Keithley 149 Instruction Manual
Milli-microvoltmeter (32 pages)
Measuring Instruments Keithley 193 Instruction Manual
System dmm (179 pages)
Related Products for Keithley 172
Keithley 1793
Keithley 148
Keithley 196 DMM
Keithley 181
Keithley 194
Keithley 1920
Keithley 196
Keithley 1992
Keithley 182
Keithley 153
Keithley 182-M
Keithley 193A
Keithley 192
Keithley 1910
Keithley 151
Keithley 149
This manual is also suitable for:
173
1722
1728
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL