Properties R134A
HFC refrigerant - classification according to ISO 817 - A1 (non-toxic, non-flammable), GWP (global warming potential) 1 430,
critical pressure 41 bar, critical temperature 101.1°C.

1.4. Legislation and security

FLOWAIR has implemented and applies a quality system for the design and manufacture of cooling and air conditioning
equipment according to ISO 9001: 2015. The design and manufacture of HCS units have been certified in accordance with
Directive 2014/68 / EU. The declaration of conformity is given in Annex No. 1 to this manual.
Basic European directives and standards related to ensuring the functionality and safety of cooling equipment:
Machine Directive (MD)
Electromagnetic Compatibility Directive (EMC)
Low Voltage Directive (LVD)
Pressure Equipment Directive (PED)
EU regulation Refrigerant Gases
European standard for Refrigerating systems
It is essential to follow all safety warnings and precautions contained in this manual. Failure to follow these rules

Specialized operator

The operator must ensure the professional installation, operation, maintenance and servicing of the system by a specialist
operator if his organization does not meet the requirements of a specialist operator. The device must be installed and
connected to the electrical / hydraulic network by specialized and qualified persons. Maintenance should only be entrusted
to those companies that specialize in servicing cooling systems.
Easy maintenance of the device without opening the covers and without interfering with the system can be performed by
trained personnel. All other operations must be performed by qualified personnel. Servicing cooling systems can pose a real
risk of injury (especially high voltage and high pressure).
Specialized personnel are personnel who have the necessary equipment, facilities and experience, as well as the appropriate
qualifications for servicing and operating cooling and electrical equipment, as well as construction equipment.
Installation, commissioning and maintenance of cooling equipment are dangerous operations. The basic risks that
may occur when operating the equipment (EN ISO 12100 - Safety of machinery) are listed below.
High pressure is used in the system
The components of the electrical system are live - risk of injury due to contact with terminals and cables
Hot surfaces, pressurized components - there is a pipe with compressed gases in the system, there is a danger
- gushing operating media or flying objects
Sharp edges - air condensers have sharp aluminum fins
Each device is equipped with a main / safety electrical switch, which can be used to safely disconnect the device from
When operating the device, use protective equipment - gloves, goggles, etc..
!!! SAFETY WARNINGS!!!
could result in serious injury or death.
!!! SAFETY WARNINGS!!!
INFORMATION
the electrical network.
FLOWAIR sp. z o.o. / OMSAC210708EN
2006/42/EC
2014/30/EU
2014/35/EU
2014/68/EU
517/2014
EN378 1 - 4