CONTROL PANEL

Electronic Control Panel & Remote Control
Note: This control panel display always shows the
room temperature in Fan Mode except when setting
the temperature and timer.

Normal Operating Sounds

You may hear a pinging noise caused by water
hitting the condenser on rainy days, or when the
humidity is high. This design feature helps re-
move moisture and improve efficiency.
You may hear the thermostat click when the
compressor cycles on and off.
Water will collect in the base pan during rain
or days of high humidity. The water may over-
flow and drip from the outside part of the unit.
The fan may run even when the compressor is
not on.
Power Button (1): Turn the air conditioner on
and off.
Digital Display (2): Will display set temperature
when the unit is in Cool, Dry, Auto, Sleep, Energy
Saver mode, and display current room temperature
when in Fan mode.
Temperature Set (3/4): Use these buttons on the
.
control panel or remote to increase or decrease the
Set Temperature.
Fan Speed (5): Use the fan speed but-
ton to change the fan speed. Choose
between high, medium, and low.
Mode Button (6): Press the MODE button to
cycle through the various modes: Cool, Dry, Fan,
Auto, Sleep, Energy Saver
Timer Set (7): Use these buttons on the control
panel and remote control to set the timer. Each
press of the ▲or▼ button will increase or de-
crease the timer.
Auto-On Timer: When the air conditioner is off,
it can be set to automatically turn on in 1-24
hours at the previous set mode and fan settings.
To set the Auto-on Timer, press the DELAY
TIMER button on the unit or remote control.
Timer can be set in 1 hour increment.
Auto-off Timer: When the air conditioner is on, it
can be set to automatically turn off in 1-24 hours.
To set the Auto-off Timer, press the DELAY
TIMER button on the unit or remote control. Timer
can be set in 1 hour increment.
Once timer is set, TIMER ON/OFF indicator on con-
trol panel will light up, the set temperature will also,
shown on digital display. To see the remaining time,
press DELAY TIMER button. To change the timer
settings, use the ▲or▼ on control panel or remote
control.
During preview of timer setting, press DELAY
TIMER button once to display set time, press the
button one more time to cancel the settings.
Filter Reset (8): After the fan rotates for 250 total
hours, the filter check light will turn on to remind
the user to clean the filter. Press the FILTER RE-
SET button to reset the reminder once the filter is
cleaned.
Signal Receiver (9): Point the remote control to
the air conditioner when sending instruction to the
unit.