Westlock 2300 Ex ia Position Monitor – ATEX / IECEx Certified. 
With Mechanical Switches, Inductive Proximity Sensors or Magnum Proximity Switches. 
1.0 Introduction 
 
The 2300 Ex ia series of Position Monitors are available in two materials, Aluminum A360.2 or Stainless Steel CF8M / 316 
which provide end of travel indication by the means of either electrical switch or inductive sensors mounted within the 
enclosure. These are activated by cams / triggers mounted on the rotary shaft. 
 
The enclosure construction comprises of a shaft passing through the enclosure housing and cover, when fitted with visual 
indicator, and has an integral gasket seal with up to two 'O'ring seals in the bearing areas.  
 
The enclosure has the option of up to four entries for connection to an external power source in a combination of the 
following sizes; M20 x 1.5p, M25 x 1.5p, 1/2"–14NPT, 3/4"‐14 NPT, Pg13.5 or any other suitable thread that can maintain 
IP6X ingress rating. Standard offering is two or four of the same thread type / size. 
 
 
2.0 Product Certification 
 
Ex ia II* T* G* 
Ex tb IIIC T135°C Db IP6X 
Tamb ‐*°C TO +*°C 
IECEx SIR 14.0056X 
 
This equipment may be used in a CAT 1, 2 or 3 Gas and CAT 2 or 3 Dust environments with apparatus groups covering IIA, 
IIB and IIC (dependent on the components fitted inside the enclosure). 
 
The products are certified to temperature classes between T1 through to T4 or either T5 or T6 internal component 
dependent. The maximum ambient temperature range is ‐40 to +*°C (dependent on enclosure material and internal 
components). 
NOTE – A special construction is approved to be used at ‐50°C to +*°C when used with certain inductive proximity 
sensors and seal. 
* The marked ambient range shall be 5 Kelvin less than the allowed ambient range of the internal devices specified in the 
individual certificates. 
 
The 2300 Series monitors are certified to the following standards;
 
EN 60079‐0: 2012 
 
EN 60079‐11: 2012   
EN 60079‐31:2009 
 
 
 
IEC 60079‐0: 2011 Ed 6.0 
IEC 60079‐11: 2011 Ed 6.0 
IEC 60079‐31:2008 
 
 
 
 
 
 
 
 
 
 
280 N. MIDLAND AVE., STE 258, SADDLE BROOK, NJ 07663 TEL: 201-794-7650 FAX: 201-794-0913
1/20/2016
 
 
Explosive atmospheres ‐ Equipment ‐ General requirements 
 
Explosive atmospheres ‐ Equipment protection by Intrinsic safety "i" 
 
Explosive atmospheres ‐ Equipment dust ignition protection by enclosure "t" 
 
Explosive atmospheres ‐ Equipment ‐ General requirements 
 
Explosive atmospheres ‐ Equipment protection by Intrinsic safety "i" 
 
Explosive atmospheres ‐ Equipment dust ignition protection by enclosure "t" 
PENTAIR VALVES & CONTROLS.
TECHUK-95 REV 1 ECN#12787-E
nnnn 
 II * GD 
Ex ia II* T* G* 
Ex tb IIIC T135°C Db IP6X 
Tamb ‐*°C TO +*°C 
SIRA 14 ATEX 2154X 