6. Click Save to save the settings.
7. Click Arming Schedule tab, click Edit to set the schedule time for each rule,
and click Save to save the settings.
8. Click Alarm Linkage tab, check the checkbox of corresponding linkage
method for each rule, and click Save to save the settings.
❖ Advanced Configuration
● Parameter
Configure the following parameters to detail the configuration.
Detection Sensitivity [0~4]: Refers to the sensitivity of the camera detects a target.
The higher the value, the easier a target be recognized, and the higher the
misinformation is. The default value of 3 is recommended.
Background Update Rate [0~4]: It refers to the speed of the new scene replaces the
previous scene. The default value of 3 is recommended.
Single Alarm: If single alarm is selected, the target in the configured area will trigger
the alarm for only once. If it is not checked, the same target will cause the continuous
alarm in the same configured area.
Leave Interference Suppression: Check this checkbox to stop the interference
caused by the leaves in the configured area.
Output Type: Select the position of the frame. Target center, bottom center, and top
centers are selectable. E.g.: The target will be in the center of the frame if target center
is selected.
User Manual of Network Camera
Figure 6-69 Advanced Configuration
114