BenQ SH753P User Manual page 64

Table of Contents

Advertisement

Indicators
Light
Power
Temp
Power events
Orange
Off
Green
Off
Flashing
Green
Off
Orange
Off
Flashing
Lamp events
Off
Off
Off
Off
Thermal events
Red
Red
Red
Red
Flashing
Red
Green
Red
Green
Flashing
Green
Red
Green
Red
Flashing
Green
Green
Green
Green
Flashing
Green
Red
System events
Green
Off
Red
Off
Flashing
Red
Off
Off
Green
Green
Off
Red
Red
Off
Red
Off
Green
64
Maintenance
Status & Description
Lamp
Off
Stand-by mode
Off
Powering up
Off
Normal operation
Off
Projector is cooling.
Orange
The lamp ignition is not lit up.
Flashing
Red
1.
The projector needs 90 seconds to cool down. Or
2.
Please contact your dealer for assistance.
Off
Off
The fans are not
working.
Off
Off
Off
Temperature 1 error (over limited temperature).
Off
Thermal sensor 1 open error.
Off
Thermal sensor 1 short error.
Off
Thermal IC #1 I2C connection error.
Red
Thermal break error.
Red
The projector has shutdown automatically. If you try to re-
Off
start the projector, it will shutdown again. Please contact your
dealer for assistance.
Red
Lamp door is open. Please check if the lamp door is open or
Red
not closed properly.
Orange Lamp life exhausted.
Red
Download.
Off
LAN download fail.
Off
LAN download processing.
The projector has shutdown
automatically. If you try to re-start
the projector, it will shutdown
again. Please contact your dealer for
assistance.

Advertisement