Maytag MDE18CSAZW0 Installation Instructions Manual page 14

Commercial dryer gas or electric
Table of Contents

Advertisement

Available languages

Available languages

DRYER VENTING REQUIREMENTS
Vent Hoods
4" (102 mm) Diameter Exhaust Hoods
louvered hood
angled hood
Vent System Length
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks, bushes, or snow).
a
L$
12"
ee
———__V (305 mm)
Maximum Vent Length/Vent Connection
Maximum
length of vent system depends upon the type of
vent used, number of elbows, and type of exhaust hood.
Vent System Chart (Rigid Metal Vent)
No. of
Box and
Angled
90° Turns _ Louvered Hood
Hood
0
130 ft. (39.6 m)
129 ft. (39.3 m)
1
125 ft. (38.1 m)
119 ft. (36.3 m)}
2
115 ft. (35.1 m)
109 ft. (33.2 m)
3
106 ft. (32.3 m)
100 ft. (30.5 m)
4
98 ft. (29.9 m)
92 ft. (28.0 m)
For vent systems not covered by the vent specification chart,
see your parts distributor.
Provision must be made for enough air for combustion and
ventilation. (Check governing codes and ordinances.) See
"Recessed Area and Closet Installation Instructions" in the
"Location Requirements" sections.
A 4" (102 mm) outlet hood is preferred. However, a 21/2"
(64 mm) outlet exhaust hood may be used. A 2!" (64 mm)
outlet creates greater back pressure than other hood types.
For permanent installation, a stationary vent system is
required.
Connect Vent
1. If connecting to existing vent, make sure the vent is clean.
2. Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer.
Vent collar
NOTE: Do not remove vent collar.
14
3. Tighten hose clamp with Phillips screwdriver.
4. Make sure the vent is secured to exhaust hood with
a 4" (102 mm) clamp.
Ss
5. Move dryer into final position. Do not crush or kink vent.
Make sure dryer is level.

Advertisement

Table of Contents
loading

Table of Contents