Maytag 4KMEDX505BW0 Installation Instructions Manual page 9

Hide thumbs Also See for 4KMEDX505BW0:

Advertisement

Available languages

Available languages

The maximum length using a 51 mm x 152 mm (2"x 6")
rectangular vent with 2 elbows and a 64 mm (2-1/2") exhaust
hood is 2,4 m (8 ft).
For exhaust systems not covered by the Vent System Chart (such
as multiple unit hookups, plenums, and power-assist fans), see
Service Manual. (To purchase the Service Manual, contact your
local authorized service dealer.)
INSTALL VENT SYSTEM
1,
Install exhaust
hood
305 rnm
(12"rain,)
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
, Connect
vent to exhaust
hood
I
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 102 mm (4") clamp. Run vent to dryer location
using straightest
path possible. Avoid 90 ° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
CONNECT VENT
1, Connect
vent to exhaust
outlet
Using a 102 mm (4") clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 102 mm (4") clamp.
2,
Move dryer to final location
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.