Anleitung_NHW_3600_SPK7__ 03.07.13 10:12 Seite 10
GBR
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
2. Layout and items supplied (Fig. 1)
2.1 Layout
1. Suction connector (R1 female thread)
2. Pressure switch
3. Pressure connection (R1 female thread)
4. Pressure gauge
5. Water filler screw
6. Water drain screw
7. Pressure tank
2.2 Items supplied
Open the packaging and take out the equipment
n
with care.
Remove the packaging material and any
n
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
n
Inspect the equipment and accessories for
n
transport damage.
If possible, please keep the packaging until the
n
end of the guarantee period.
IMPORTANT
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
foils or small parts. There is a danger of
swallowing or suffocating!
Domestic waterworks
n
Suction hose 4m
n
Original operating instructions
n

3. Proper use

Applications
Irrigation and watering of green areas, vegetable
n
beds and gardens.
Operation of lawn sprinklers.
n
For drawing water from ponds, streams, rainwater
n
butts, rainwater cisterns and springs
For supplying service water
n
10
Transport media:
For the pumping of clear water (fresh water),
n
rainwater or light suds/service water.
The maximum temperature of the fluid must not
n
exceed +35°C if the equipment is operated
permanently.
Do not use the equipment to pump inflammable,
n
gassing or explosive fluids.
The pumping of aggressive liquids (acids, alkalis,
n
silo seepage etc.) as well as liquids with abrasive
substances (sand) must likewise be avoided.
This equipment is not designed to convey
n
drinking water.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufacturer
will be liable for any damage or injuries of any kind
caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Technical data

Mains connection:
Power consumption:
Pumping rate max.
Delivery head max.
Delivery pressure max.
Suction height max.
Pressure connection:
approx. 33.3 mm (R1 female thread)
Suction connection:
approx. 33.3 mm (R1 male thread)
Water temperature max.
Tank capacity:
Cut-in pressure approx.:
Cut-out pressure approx.:
Protection type:
230 V ~ 50 Hz
600 W
3600 l/h
40 m
0.40 MPa (4.0 bar)
8 m
35°C
20 l
0.15 MPa (1.5 bar)
0.3 MPa (3 bar)
IPX4