IR6LT –
WITH TEMPERATURE CONTROL
The mobile dryer is equipped with an automatic
temperature control. This enables optimum drying/
curing results within the shortest possible time.
The temperature control (pyrometer) measures the
temperature contactless by optics. The laser pointer
indicates where the temperature is measured in the
material cured.
The mobile dryer is also equipped with two power levels,
flash off (50% power) and full bake (100% power) whith
individually timers.
START-UP
Turn the main switch on. This will initiate the electronics.
Four dots will sequentially blink to indicate the start-up. Next
the top display will show 1P (1-phase) OR 3P (3-phase). The
lower display shows the supply frequency 50 or 60 Hz.
When the start-up sequence is over, the displays show
the last used curing values. The upper window shows
flash off set time in minutes and the lower window
shows the maximum temperatur allowed or full bake set
time in minutes. Use the toggle button to alter the lower
window beetween maximum temperature or minutes
settings for the fullbake. Use alse the toggle button to
alter the use of one or two cassettes.
SETTINGS
Use the + and - buttons below the displays to change
the settings. Use the toggle button to change between
maximum temperatur setting and minutes for full bake
setting. Pressing the buttons continously will rapidly
increase the setting. Each timer can be set between
0 and 30 min and the temperature between 20°C and
99°C. The settings will remain even after power-off and
serve as default for the next curing operation.
CURING
Start the laser by pressing the On/Off button once.
Adjust the cassette so the laser point is visibale on the
surface to be cured and temperatur measured. Start the
curing by pressing the On/Off button a second time.
The active timer will flash and the heater will switch off
automatically when the set times have elapsed. After
idling for 30 minutes, the unit enters stand-by mode
when a dot in each display flashes. Pressing any button
will activate the unit again.
www.carlisleft.com
TRU CURE IR6LT – OPERATING INSTRUCTIONS
FLASH OFF TIMER
FLASH OFF SETTINGS
FULL BAKE TIMER
FULL BAKE SETTINGS
INDICATOR LAMP TEMP/TIME
TOGGLE BUTTON TEMP/TIME/CASETTE
ON/OFF BUTTON
MAIN SWITCH – LOCATED ON THE
RIGHT HAND SIDE
Minimum curing distance is 50 cm and optimal curing
distance is 60 cm.
The pyrometer measure the temperature at a
diametar of 10cm around the laserdot.
Make sure that you don't measure the temperature on
glass, tyres or outside the object (10 cm diameter
around the laser dot). Otherwise, the result between
the programmed temperature values and actual
values may differ. This may lead to unsatisfactory
results.
The FLASH OFF timer controls the duration of the half
power output of the emitters. The FULL BAKE timer
controls the duration of the full power output of the
emitters. If both FLASH OFF and FULL BAKE timers
are used, the FLASH OFF timer will count down first
and upon switching off it will engage the FULL BAKE
timer automatically.
Alterning between temperature and timer in the lower
window is possible even during curing.
To stop the unit before the time is out, press the
On/Off button.
If the temperature inside the control unit rises over
65°C (149°F), the unit switches off. The upper display
will show Ot (over temperature) and the lower the
actual temperature. Automatic reset when the
temperature falls below 55°C (131°F) and the unit is
ready for operation again.