Summary of Contents for Carlisle TRISK DEVILBISS TRU-CURE IR6LT Series

  • Page 1 SERVICE MANUAL ORIGINAL LANGUAGE TRU-CURE IR6LT TC-IR6LT-01 TRU-CURE IR6LT (904112 FOR USA) (NORTH AMERICA) TRU-CURE IR6LT TC-IR6LT-02 (UNITED KINGDOM) TRU-CURE IR6LT TC-IR6LT-03 (EUROPE) For other languages of this service manual as well as additional product information, please scan the QR code above. SB-81-016-R1 (11/2023) 1 / 12 www.carlisleft.com...
  • Page 2 EC Declaration of conformity According to testing institutes and according to the machine directive the Trisk Devilbiss products in this manual are not defined as machines, wherefore the machine directive reference cannot be included in this declaration. In accordance with EN 17050-1:2010 Hedson Technologies AB Box 1530 SE 462 28 Vänersborg...
  • Page 3 Declaration of conformity UKCA Hedson Technologies AB Box 1530 SE 462 28 Vänersborg Sweden declare under our sole responsibility that the products Trisk Devilbiss TRU-CURE IR6LT that are used to accelerate the drying of paint, to which this declaration relates, are in conformity with the following standards EN 60335-1:2002 Specification for safety of household and similar electrical appliances +A11+A1+A12...
  • Page 4 In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as follows: WARNING NOTE CAUTION Hazards or unsafe practices which Hazards or unsafe practices which could result in severe personal Important installation, operation or could result in minor personal injury, injury, death or substantial property maintenance information.
  • Page 5 TRU CURE IR6LT – GENERAL INFORMATION FIELD OF APPLICATION INSTRUCTION TO THE OWNER The Trisk Devilbiss IR6LT are designed to provide an The owner of the mobile dryer must produce clear operating accelerated and even cure of most automotive refinishing instructions, adapted to local site conditions and applicable materials.
  • Page 6 TRU CURE IR6LT – OPERATING INSTRUCTIONS IR6LT – WITH TEMPERATURE CONTROL FLASH OFF TIMER The mobile dryer is equipped with an automatic temperature control. This enables optimum drying/ curing results within the shortest possible time. FLASH OFF SETTINGS The temperature control (pyrometer) measures the temperature contactless by optics.
  • Page 7: Maintenance

    MAINTENANCE LAMP REPLACEMENT NOTE Only use original Trisk Devilbiss lamps with the correct power rating. 1. Disconnect power supply. 2. Remove the mesh. 3. Remove the old lamp. 4. Install new lamp in reverse order. CAUTION Do not touch the new lamp with your fingers. Remove the protective paper on the lamp after you have installed it.
  • Page 8: Spare Parts

    SPARE PARTS PICTURE PART NO. DESCRIPTION 410-1000 1 KW IR QUARTS LAMP 991000 for USA 410-1001 REFLECTOR 991001 for USA 410-1002 PROTECTIVE MESH 991002 for USA 410-1003 1 KW CASSETTE COMPLETE 991003 for USA 410-1030 2 KW CASSETTE COMPLETE IR6L 3 PHASE 991030 for USA (NO TEMPERATURE SENSOR) (EU+UK) 410-1032...
  • Page 9 ELECTRICAL DIAGRAM 230V SINGLE PHASE SB-81-016-R1 (11/2023) 9 / 12 www.carlisleft.com...
  • Page 10 ELECTRICAL DIAGRAM 400V 3-PHASE www.carlisleft.com 10 / 12 SB-81-016-R1 (11/2023)
  • Page 11 NOTES SB-81-016-R1 (11/2023) 11 / 12 www.carlisleft.com...
  • Page 12: Warranty Policy

    This product is covered by Carlisle Fluid Technologies’ materials and workmanship limited warranty. The use of any parts or accessories, from a source other than Carlisle Fluid Technologies, will void all warranties. Failure to reasonably follow any maintenance guidance provided may invalidate any warranty.