Function

minimum use time 10 sec.

Supplied equipment

SLP 32RZ - Code Nr. 01325, SLP 33RZ - Code Nr. 01335

Installation

3
8
1
length of
5
vertical plumbing
min 150 mm
4

Recommended accessories

SLD 04
ISO 9001:2000
Automatic urinal radar flushing system SLP 32RZ, SLP 33RZ
2
1 - water inlet to the urinal
2 - electronics with radar senzor
3 - outlet fiting with sealing
4 - waste outlet Ø 50 mm
5 - power input 230V/50Hz
6 - urinal
7
7 - waste siphon
8 - electromagnetic valve
Remote control for the parameters adjustment
Mounting instructions
after 6 hours non use
1
Ø = 14
230V/50 Hz

Properties

flushing time 0,5 - 15,5 sec
SLP 32RZ = 200
SLP 33RZ = 240
water inlet
150
Ø 50 mm
waste
outlet
using time 6 - 15 sec
Ø = 14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLP 32RZ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sanela SLP 32RZ

  • Page 1 6 hours non use flushing time 0,5 - 15,5 sec using time 6 - 15 sec Supplied equipment SLP 32RZ - Code Nr. 01325, SLP 33RZ - Code Nr. 01335 Installation SLP 32RZ = 200 SLP 33RZ = 240 water inlet Ø...
  • Page 2 24V DC 3/4“ 230V/50Hz 10 sec 24V DC 24 V DC 230V/50 Hz ONE AUTOMATIC FLUSH Service It is recommend to check up the sifter of electromagnetic valve once a year, because of there is a possibility that valve could be fouled up. Checking of tightening of screw conections and connectors contact surfaces is also recommend once a year.

This manual is also suitable for:

Slp 33rz0132501335

Table of Contents