Download Print this page

Sanela SLP 32RB Mounting Instructions

Automatic urinal radar flushing system

Advertisement

Quick Links

Function
minimum use time 10 sec.
Supplied equipment
SLP 32RB - Code Nr. 11327, SLP 33RB - Code Nr. 11337
Installation
3
8
1
length of
vertical plumbing
min 150 mm
4
Recommended accessories
SLD 04
ISO 9001:2000
Automatic urinal radar flushing system SLP 32RB, SLP 33RB
2
1 - water inlet to the urinal
2 - electronics with radar senzor
3 - outlet fiting with sealing
4 - waste outlet Ø 50 mm
5 - box with bateries
7
6 - urinal
5
7 - waste siphon
8 - electromagnetic valve
Remote control for the parameters adjustment
Mounting instructions
Properties
flushing time 0,5 - 15,5 sec
after 6 hours non use
1
Ø = 14
Ø 50 mm
waste
outlet
using time 6 - 15 sec
SLP 32RB = 200
SLP 33RB = 240
water inlet
Ø = 14
150

Advertisement

loading

Summary of Contents for Sanela SLP 32RB

  • Page 1 6 - 15 sec minimum use time 10 sec. after 6 hours non use Supplied equipment SLP 32RB - Code Nr. 11327, SLP 33RB - Code Nr. 11337 Installation SLP 32RB = 200 SLP 33RB = 240 water inlet Ø...
  • Page 2 3/4“ 10 sek ATTENTION ! 4 pcs alkaline batteries AA 2700 mAh ( Battery life approx. 2 years at 4000 uses monthly ) Electronics is switched on 15 minutes after the insertion of batteries. One flush starts automatic immediate after that. Electronics is switched on 15 minutes after the insertion of batteries.

This manual is also suitable for:

Slp 33rb