The PWR light is red.
1. Communication has been lost between the power centers and cells. Verify the communication
connection. See "POWER UP THE SYSTEM" step 3, page 7.
2. If the communications are connected, replace the master board in the PRIMARY power center.
The cell is not powered up
1. Check fuse, replace if open.
2. Check if cell connector is plugged and twist-locked all the way in.
Fuse is blown
1. Replace with 12 amp ceramic fuse. DO NOT USE 10AMP glass (a common fuse), it is not reliable
and might fail later. If the fuse blows again, replace the cell.
2. Verify the Power center is not wired for 110VAC and has 220VAC applied to it. THIS IS NOT
COVERED BY THE WARRANTY.