Download Print this page
Global Industrial 412672 User Manual

Global Industrial 412672 User Manual

Digital compact bench scale

Advertisement

Quick Links

USER MANUAL
Digital Compact Bench Scale
Model no. 412672, 412673, 412674, 412675

Advertisement

loading
Need help?

Need help?

Do you have a question about the 412672 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Global Industrial 412672

  • Page 1 USER MANUAL Digital Compact Bench Scale Model no. 412672, 412673, 412674, 412675...
  • Page 2 Turn on the scale, press and hold the M+/PRINT/ key until the ↵ countdown sequence has completed. The LCD display will show auxiliary number 61 , release the key and the scale will off. Display Model no. 412672, 412673, 412674, 412675...
  • Page 3 When set and change into PCS,PCS marker light,Optional number by ▲ switch: C 10PCS、C 20PCS、C 50PCS、C 100PCS、C 200PCS,put the corresponding number of objects on the scale, after the stable press key, complete the number of samples. ↵ Model no. 412672, 412673, 412674, 412675...
  • Page 4 232 3 or 232 6) : Works as enter key in setup mode ↵ ※ Error messages: Err N Unstable internal count -OL- Overload, when the weight is heavier than the full capacity + 9d of the scale Model no. 412672, 412673, 412674, 412675...
  • Page 5 Press the key to calibrate zero point (Press the ↵ ESC key to terminate calibration back to menu ECF-1) ↓ ↵ 150.00 Use ◀,▶,▲ and then key to enter the weight to ↵ be calibrated Model no. 412672, 412673, 412674, 412675...
  • Page 6 Place the required weight mass onto the scale as indicated on display and press the key to calibrate ↵ the scale ↓ (Press the ESC key to terminate calibration back to menu ECF-3) ↵ 150.00 Calibration procedure completed and the scale will Model no. 412672, 412673, 412674, 412675...
  • Page 7 ESC key to exit ↵ menu and back to weighing mode ↑↓ ◀ ▶ UF-6 Press the key to start or press the ESC key to exit ↵ menu and back to weighing mode ↑↓ ◀ ▶ Model no. 412672, 412673, 412674, 412675...
  • Page 8 A --Buzzer Conditions: 0 = Stable not required to buzz 1 = Stable required to buzz B -- LCD display Output: 0 = Stable not required to output 1 = Stable required to output C -- Buzzer beeps at: 0 = Buzzer off Model no. 412672, 412673, 412674, 412675...
  • Page 9 Auto power-off timer up to 99 minutes (AoFF01~AoFF 99) ※ Factory default: AoFF 10 UF-3 Press the key to start or press the ESC key to exit ↵ menu and back to weighing mode ↓ Model no. 412672, 412673, 412674, 412675...
  • Page 10 (for HOLD 1 only) ※ This function is locked when LF 6 is set as “Approval Version” ※ Factory default: HOLD 0 UF-5 Press the key to start or press the ESC key to exit ↵ Model no. 412672, 412673, 412674, 412675...
  • Page 11 ↵ setups or press the ESC key to exit menu and back to weighing mode UF-6 RS232 : 232 0 RS232 disable 232 1 Stable output – Format 1 Model no. 412672, 412673, 412674, 412675...
  • Page 12 Gross Weight Fixed 18 BYTES ASCII (kg g t lb) 1 2 1 1 2 1 1 2 3 4 5 6 7 8 1 2 1 2 HEAD1 HEAD2 DATA UNIT CR LF Model no. 412672, 412673, 412674, 412675...
  • Page 13 Fixed 13 BYTES ASCII (pcs) DATA UNIT CR LF Output examples : 1. Example +0.876 kg stable net weight : 2. Example -1.568 lb unstable gross weight : 3 Example -20. 5.40 lb oz unstable gross weight : Model no. 412672, 412673, 412674, 412675...
  • Page 14 MC key, and the accumulative weight will be removed. UF-6 Press the key to start or press the ESC key to exit ↵ menu and back to weighing mode ↓ ↵ Use ▲ and then key to enter RS232 output ↵ Model no. 412672, 412673, 412674, 412675...
  • Page 15 ESC key to exit menu and back to weighing mode UF-8 Zero Weight Display Condition : 0 Off 1 One division not to display at zero 2 Two divisions not to display at zero Model no. 412672, 412673, 412674, 412675...
  • Page 16 ↓ ↵ -00- The display will show the value for 1 second ↓ 9.79450 Use ◀﹑▶ keys to see previous entered values. The display will stay at 00 if no value has been entered Model no. 412672, 412673, 412674, 412675...
  • Page 17 ↓ ↵ ◀ ▶ IP_1 Press the key to Set IP adress ↵ ↓ ↵ ◀ ▶ IP_1 Press the key to Set IP adress ↵ ..UF-10 Model no. 412672, 412673, 412674, 412675...
  • Page 18 CB20 gateway address Settings (four section) GAtE _2 GAtE _3 GAtE _4 riP_1 PC IP address (four section) riP _2 riP _3 riP _4 rPort PC port SSid_1 WiFi name that needs to be connected SSid_2 Model no. 412672, 412673, 412674, 412675...
  • Page 19 ↵ password ↓ P 0020 Press the key to enter lock section setup ↵ ↓ ↵ LF 1 Press the key to start or press the ESC key to exit ↵ Model no. 412672, 412673, 412674, 412675...
  • Page 20 ESC key to exit ↵ menu and the scale will restart automatically ↓ ↵ CAL Z Press the key to start Zero Calibration ↵ (Press the ESC key to terminate calibration back to Model no. 412672, 412673, 412674, 412675...
  • Page 21 F : Calibration Unit 1 : Metric units as calibration unit 2 : American units as calibration unit ※ The scale will not allow to continue to the next setup step if an error has occurred during the programming Model no. 412672, 412673, 412674, 412675...
  • Page 22 (Press the ESC key to exit the setup and back to menu LF 2) ↓ ↵ 100001 Use ◀﹑▶﹑▲ and then key to select weighing ↵ units ↓ (Press the ESC key to exit the setup and back to menu Model no. 412672, 412673, 412674, 412675...
  • Page 23 Press the ▶ key to calibrate zero (Press the ESC key to terminate calibration back to menu LF 3) ↑↓ ◀ ▶ Place 1/3 weight mass of full capacity onto the scale and press the ▶ key to calibrate 1/3 of the capacity Model no. 412672, 412673, 412674, 412675...
  • Page 24 (Press the ESC key to exit the setup and back to menu LF 4) ↓ ↵ LF 4 Use ◀﹑▶ and then key to continue with other ↵ setups or press the ESC key to exit menu and the scale will restart automatically Model no. 412672, 412673, 412674, 412675...
  • Page 25 Press the key to start or press the ESC key to exit ↵ menu and the scale will restart automatically ↓ ↵ nonE Use ▲ and then key to select approval or ↵ non-approval Model no. 412672, 412673, 412674, 412675...
  • Page 26 ESC key to exit menu and the scale will restart automatically LF 8 Initial Zero: SEtZ Y Reset zero point every time the scale has been switched on SEtZ n Zero point reset off ※ Factory Default: SEtZ Y Model no. 412672, 412673, 412674, 412675...
  • Page 27 (Press the ESC key to exit the setup and back to menu LF 8) ↓ ↵ LF 8 Use ◀﹑▶ and then key to continue with other ↵ setups or press the ESC key to exit menu and the scale will restart automatically Model no. 412672, 412673, 412674, 412675...

This manual is also suitable for:

412673412674412675