Page 1
Service à la clientèle US: 1-800-645-2986 Canada: 888-645-2986 US: 1-800-645-2986 Heavy Duty Pallet Digital Scales Model # 412552 Model # 412554 Model # 412556 & 412557 Read this manual thoroughly prior to Model # Floor Scale Size Load Capacity installation, operation or maintenance.
Heavy Duty Pallet Digital Scale User’s Manual Table of Contents SAFETY PRECAUTIONS PREPARATION & SET UP FEATURES SPECIFICATIONS DISPLAY AND KEY DESCRIPTION OPERATING INSTRUCTIONS CALIBRATION PROCEDURE INDICATOR PARAMETER SETTINGS CONNECTORS TROUBLESHOOTING GLOSSARY...
Heavy Duty Pallet Digital Scale User’s Manual SAFETY PRECAUTIONS Read and follow all instructions before use ● Calibration, inspections, and maintenance should be performed by professionals ● Ensure the indicator rests on a stable surface ● DO NOT disassemble or modify unity ● DO NOT exceed the rated load limit of the unit ● DO NOT step on the unit ● DO NOT jump on the unit...
Heavy Duty Pallet Digital Scale User’s Manual DISPLAY AND KEY DESCRIPTION ON/OFF Powers the Indicator On or Off if held for 2 seconds HOLD Holds the weight (5 Hold options; can be changed in parameter settings) 1. Accumulates weights TOTAL 2.
Heavy Duty Pallet Digital Scale User’s Manual OPERATING INSTRUCTIONS Power On ● Turn on the power by pressing the power button for 2 seconds. Once on, the scale will flash the voltage and then begin to auto-check and count down from 0-9 sequentially before entering the weighing mode Note: Anything on the scale before powering on will automatically be tared out.
Page 8
Heavy Duty Pallet Digital Scale User’s Manual Counting Function ● The counting function is used to count a high volume of identical parts. You can do this by setting a sample and then either adding to the sample or taking away from the sample to count the number of objects on the scale ● In weighing mode: Put a sample weight on the scale (Sample options are 5, 10, 20, 50, 100, 200, 500)
Page 9
Heavy Duty Pallet Digital Scale User’s Manual Hold There are 4 different hold functions you can choose from in the C11 parameter 1. Peak Hold: Grabs the highest weight (for materials testing, ie. tension and pulling force) ● Press the HOLD key then add weight to the scale ● The indicator will show the highest weight it recorded and hold it on the screen until a higher weight is placed on the scale 2.
Heavy Duty Pallet Digital Scale User’s Manual CALIBRATION PROCEDURE C C A A L L I I B B R R A A T T I I O O N N P P R R O O C C E E D D U U R R E E Turn on the scale by holding ON/OFF(!) for 2 seconds.
Page 11
Heavy Duty Pallet Digital Scale User’s Manual 23. Enter the calibration weight value you will use (at least 10% of max capacity you set in C04 by using UNIT◄ and COUNT► to move the cursor left and right, and TARE T and ZERO • move the values down and up.
Heavy Duty Pallet Digital Scale User’s Manual INDICATOR PARAMETER SETTINGS The parameter settings menu has a calibration section (C01 to C07 explained above) and a parameter settings section (C08 and up). To access the calibration section the seal switch (located at one corner of the PCB) must be OFF. This will allow access to all C01 and up settings.
Page 13
Heavy Duty Pallet Digital Scale User’s Manual Function Parameter Settings/Options Restore Default Settings 0 = do not restore 1 = restore to default settings Warning Tone 0 = turn off warning tone 1 = turn on warning tone Automatic 0 = turn off auto power off Power Off 10 = power off automatically if no change within 10 minutes 30 = power off automatically if no change within 30 minutes...
Page 14
Heavy Duty Pallet Digital Scale User’s Manual Function Parameter Settings/Options 0 = turn off manually zero setting 1 = ±1% max capacity 2 = ±2% max capacity Manual 4 = ±4% max capacity Zero 10 = ±10% max capacity Range 20 = ±20% max capacity 100 = ±100% max capacity 0 = no initial zero setting...
Page 15
Heavy Duty Pallet Digital Scale User’s Manual Function Parameter Settings/Options 0 = turn off noise filter 1 = 1 digital filter strength Noise Filter 2 = 2 digital filter strength 3 = 3 digital filter strength yy.mm.dd mm.dd.yy Print Time and Date dd.mm.yy yy.mm.dd Analog Output Setting...
Page 16
Heavy Duty Pallet Digital Scale User’s Manual Table 2. Unit Conversion Parameter Settings Parameter Settings Units Available C01= 3 & C12= 0 gram only C01= 4 & C12= 0 oz only C01= 1 & C12= 0 kg only C01= 1 & C12= 1 kg/lb C01= 1 &...
Page 17
Heavy Duty Pallet Digital Scale User’s Manual Table 3. Default Parameter Settings Function Parameter Default Setting Weighing Unit Decimal Setting Graduation Setting Maximum Capacity 1000 Zero Calibration Calibration Restore Default Warning Tone Automatic Power Off Power Saving Mode Hold Function Unit Conversion Upper Limit Alarm 000000...
Heavy Duty Pallet Digital Scale User’s Manual CONNECTORS Connecting load cells to the indicator ● The indicator can connect with 6 load cells of 350Ω at most ● 4 wire or 6 wire load cell connections are both okay ● Please contact us directly if you have other special needs for your application ● There are two connection methods between the load cell and indicator Quick Disconnect as shown below: FIGURE 2: QUICK DISCONNECT CONNECTION DIAGRAM...
Page 19
Heavy Duty Pallet Digital Scale User’s Manual Table 4. Wiring Color Code Signal Name Color Code Description +Exe/ +EX Positive excitation voltage to load cell +IN / +SIG GREEN Positive output signal from load cell HD / SHLD YELLOW/THICK BLACK Shield Wire -IN / -SIG WHITE...
Page 20
Heavy Duty Pallet Digital Scale User’s Manual Remote Display Continuous Sending Mode (C18=1) For use with a Scoreboard/Remote Display Note: Baud Rate must be set to 1200 (C19 = 0) Output Continuous Format State A Bits0,1,2 Decimal point position XXXXXX0 XXXXXXX XXXXX.X XXXX.XX...
Page 21
Heavy Duty Pallet Digital Scale User’s Manual Print Mode (C18 = 2) For printing on a non-adhesive ticket printer. Parameters 16, 17, 30, & 42-45 all effect your ticket print out. Normal weighing ticket printout example: Date: 05/01/2017 Time: 11:30:52 Net: 25.6lb Tare:...
Page 22
Heavy Duty Pallet Digital Scale User’s Manual Command Request Mode (C18=3) In this mode, the indicator can receive ASCII commands as listed below Command Name Function Tare Save and clear tare Zero Zero gross weight Print Print the weight G.W/ Read gross weight or net weight Kg/lb Kg/lb conversion...
Page 23
Heavy Duty Pallet Digital Scale User’s Manual Print to Adhesive Label Printers (C18=5) & (C18=6) Printing formats: 05/01/2017 Date: Date: XX.XX. XX (yy.mm.dd) Time: 11:30:52 Time: XX.XX.XX (hh.mm.ss) Net: 25.6lb 6.00kg (net weight) Tare: 1 0 .3 l b 2.88kg (tare) TARE Gross: 35.9lb...
Heavy Duty Pallet Digital Scale User’s Manual TROUBLESHOOTING Issues/Error Codes Possible Causes Suggested Actions 1. Loose power cord 1. Ensure the power cord is plugged in The scale does not turn on 2. Ensure the power source works. Test Outlet is defective the power source by connecting a different appliance to the same outlet to check if it’s operational.
Page 25
Heavy Duty Pallet Digital Scale User’s Manual Calibration is no good Ensure scale is leveled Cables are not connected Check load cell connection nnnnnnn properly Check load cell input and output Load cell is defective resistance If the above actions don’t work, try the following instructions: • Check if the cable that runs from the indicator to the...
Page 26
Heavy Duty Pallet Digital Scale User’s Manual ERR6 1. Ensure the scale is leveled and does Exceed Zero Range not wobble. Turn it on with no load on the scale. 2. Press and hold the “PRINT and HOLD” key simultaneously for a few of seconds 3. The screen will read “C01”...
Heavy Duty Pallet Digital Scale User’s Manual GLOSSARY Division: The amount of increments a scale offers. How accurate the scale can be Capacity: the maximum amount the scale can contain Initial Zero Range: The percentage of weight allowed on the scale when indicator is powered on that will automatically zero.
Need help?
Do you have a question about the 412552 and is the answer not in the manual?
Questions and answers