Global Industrial 412584 User Manual

Global Industrial 412584 User Manual

Stainless steel drum digital scale w/lcd indicator 1,000lb x 0.2lb

Advertisement

Quick Links

User's manual
Customer Service
US: 1-800-645-2986
Stainless Steel Drum Digital Scale
W/LCD Indicator 1,000lb x 0.2lb
Manual del usuario
Servicio de atención al Cliente
US: 1-800-645-2986
Models: 412584
1
Manuel de l'utilisateur
Service à la clientèle
Canada: 888-645-2986
MODEL # 412584

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 412584 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Global Industrial 412584

  • Page 1 User's manual Manual del usuario Manuel de l'utilisateur Customer Service Servicio de atención al Cliente Service à la clientèle US: 1-800-645-2986 Canada: 888-645-2986 US: 1-800-645-2986 Stainless Steel Drum Digital Scale W/LCD Indicator 1,000lb x 0.2lb Models: 412584 MODEL # 412584...
  • Page 2: Table Of Contents

    User Manual Stainless Steel Drum Scale CONTENTS 1. INTRODUCTION ......................General and Safety Information ......................3 Specifications ............................5 2. INSTALLATION ......................5 Contents...............................5 Unpacking and Installation ........................5 3. OVERVIEW OF CONTROLS AND FUNCTIONS ............6 Indicator Display Character Definitions ....................6 Indicator Display ..........................7 Function Keys ............................8 4.
  • Page 3: Introduction

    User Manual Stainless Steel Drum Scale 1. I I N N T T R R O O D D U U C C T T I I O O N N G G e e n n e e r r a a l l a a n n d d S S a a f f e e t t y y I I n n f f o o r r m m a a t t i i o o n n ...
  • Page 4 User Manual Stainless Steel Drum Scale S S p p e e c c i i f f i i c c a a t t i i o o n n s s M M o o d d e e l l 4 4 1 1 2 2 5 5 8 8 4 4 M M a a x x C C a a p p a a c c i i t t y y 1000lb (500kg)
  • Page 5: Specifications

    User Manual Stainless Steel Drum Scale 2 2 . . I I N N S S T T A A L L L L A A T T I I O O N N C C o o n n t t e e n n t t s s ...
  • Page 6: Overview Of Controls And Functions

    User Manual Stainless Steel Drum Scale 3. OVERVIEW OF CONTROLS AND FUNCTIONS Indicator Display Character Definitions...
  • Page 7: Indicator Display

    User Manual Stainless Steel Drum Scale Indicator Display - Scale is zeroed, gross weight is 0, tare is 0.  - Scale is stable.   NET - Display reading is net weight; tare is not 0.  Total - Display data is accumulated total times, weight, pieces, or percentage. ...
  • Page 8: Function Keys

    User Manual Stainless Steel Drum Scale Function Keys MODE DEFINITION Weighing, <3 seconds Enters or exits HOLD mode Counting, or >3 seconds Enters SETUP mode Percent mode <3 seconds Returns to last sub-menu Input data mode >3 seconds Inputs decimal point Menu selection mode Returns to last sub-menu Weighing,...
  • Page 9: Operation Menu Structure

    User Manual Stainless Steel Drum Scale 4 4 . . O O p p e e r r a a t t i i o o n n M M e e n n u u S S t t r r u u c c t t u u r r e e E E n n t t e e r r S S e e t t u u p p M M o o d d e e 1.
  • Page 10: User Submenu

    User Manual Stainless Steel Drum Scale U U S S E E R R S S u u b b m m e e n n u u : : U U S S E E R R S S u u b b - - S S u u b b - - O O p p t t i i o o n n R R e e m m a a r r k k...
  • Page 11 User Manual Stainless Steel Drum Scale Sub- Sub- Option Remark Setting Menu1 Menu2 Yes/No=enable/disable output weight of 1% Y Y E E S S U U P P C C T T W W T T N N O O percentage.
  • Page 12 User Manual Stainless Steel Drum Scale Sub- Sub- Option Remark Setting Menu1 Menu2 Com2 output content and format set: M M U U L L T T P P L L MULTPL= the following selected item in OUT2 will be output use defined format;...
  • Page 13 User Manual Stainless Steel Drum Scale Sub- Sub- Option Remark Setting Menu1 Menu2 Y Y E E S S Yes/No=enable/disable beep after a key pressed K K E E Y Y Y Y E E S S down N N O O N N O O N N E E NONE=not beep;...
  • Page 14 User Manual Stainless Steel Drum Scale Sub- Sub- Option Remark Setting Menu1 Menu2 1-255=the range of weight is 1-255d; when current weight is less than this value, the scale can be O O T T H H E E R R N N L L D D .
  • Page 15: Operations

    User Manual Stainless Steel Drum Scale 5. OPERATIONS Change working mode Press and hold the PRINT/FUNC key, then use key to choose and confirm to enter into weighing mode or counting mode. Normal Weighing Mode 1. Power on the scale by pressing the ZERO/ON/OFF key. 2.
  • Page 16: Zero

    User Manual Stainless Steel Drum Scale Table5-2: use LB as primary unit: Calibration Display division value in different weight unit that can be used division value lb:oz Not available Not available 0.0001lb 0.002oz Not available 0.0001lb 0.001 lb 0.0005 kg 0.5g 0.001 lb 0.02oz...
  • Page 17: Check Weighing (Data Compare) In Normal Weighing Mode

    User Manual Stainless Steel Drum Scale Note: Tare weight must be greater than zero and no more than the scale‟s maximum capacity. 4. Place the material or object to be weighed onto the scale platform. The net weight will be displayed. 5.
  • Page 18: Counting Mode

    User Manual Stainless Steel Drum Scale readability, see s s p p e e c c i i f f i i c c a a t t i i o o n n s s ) can be accumulated. This setting (U U S S E E R R - - O O T T H H E E R R - - N N L L D D .
  • Page 19: Check Counts (Counts Compare) In Counting Mode

    User Manual Stainless Steel Drum Scale select Press the T T A A R R E E / / P P R R E E S S E E T T key to enter “Get Piece Weight” S S P P L L . . P P W W T T mode.
  • Page 20: Hold Function

    User Manual Stainless Steel Drum Scale H H O O L L D D F F u u n n c c t t i i o o n n N N O O T T E E : In trade application, HOLD function should be prohibited! 1.
  • Page 21: Details About Serial Communication

    User Manual Stainless Steel Drum Scale mode according to the setting of U U S S E E R R - - H H O O L L D D - - H H L L D D . . T T I I M M . If the time of scale variation is over U U S S E E R R - - O O T T H H E E R R - - N N L L D D .
  • Page 22 User Manual Stainless Steel Drum Scale <LF> Line Feed character (hex 0AH) <CR> Carriage Return character (hex 0DH) <ETX> End of Text character (hex 03H) <SP> Space (hex 20H) Four current status bytes <P> Polarity character: “-” or “ ” ---W Reading data, 1-6 bytes (six digits) <DP>...
  • Page 23 User Manual Stainless Steel Drum Scale scale status. <LF> H <CR><ETX> If ZERO function cannot be activated, it will return to current scale status. Command: T T < < C C R R > > (54h 0dh) Response: TARE function is activated (simulate T T A A R R E E key), and then returns scale status. <LF>...
  • Page 24 User Manual Stainless Steel Drum Scale <LF><Prompt><p>W <Dp>W <CR> …… --- Line number and content are determined by setting of U U S S E E R R - - O O U U T T 1 1 / / 2 2 - - x x x x x x x x <LF><Prompt>H <CR>...
  • Page 25 User Manual Stainless Steel Drum Scale Status Byte 0=Stable weight data 1=Scale in motion 0= Within weighing range 1= Over capacity 0=Within weighing range 1= Under zero 0= Within range 1= Outside zero capture range 0= Not at center of zero 1= Center of zero always 1 always 1...
  • Page 26 User Manual Stainless Steel Drum Scale c. Key to symbols used: <ETX> End of TeXt character (03 hexadecimal). <LF> Line Feed character (0A hex). <CR> Carriage Return character (0D hex). Xxxxxx Weight characters from display including minus sign and out-of-range characters.
  • Page 27: Calibration

    User Manual Stainless Steel Drum Scale 6. Calibration Note: ① Before calibrating the scale, please prepare a standard weight (more than 10% of FS weight) for calibration. ② In the following steps, pressing ZERO/ON/OFF will show “ ”, and pressing E E X X I I T T ? ? ZERO/ON/OFF again or pressing TARE/PRESET will exit the calibration ”, then press TARE/PRESET to confirm to enter...
  • Page 28 User Manual Stainless Steel Drum Scale to the next calibration. Use key to select , use TARE/PRESET to y y e e s s n n o o confirm. If is selected, you will be directed go to step8 to end calibration; if y y e e s s n n o o selected, continue to the next step.
  • Page 29 User Manual Stainless Steel Drum Scale...
  • Page 30: Misc

    User Manual Stainless Steel Drum Scale 7. MISC View or Set Date 1. After entering SETUP mode (by pressing and holding the SETUP key for more than 4 seconds), using keys to select item, then press M M I I S S C C - - D D A A T T E E TARE/PRESET to display current time.
  • Page 31: Troubleshooting

    User Manual Stainless Steel Drum Scale - Sample goods weight to calculate unit percent weight S S P P L L . . P P C C T T - Input percentage of weighted goods I I N N P P . . P P C C T T - Accumulation times is xxx A A C C C C .
  • Page 32 User Manual Stainless Steel Drum Scale SYMPTOM PROBABLE CAUSE REMEDY Remove load on scale. 1. Load on scale exceeds allowable Wait for load to become stable. Cannot zero the limits.(2%FS) display then press the ZERO/ON/OFF key 2. Load on the scale is unstable to zero the display Piece weight is error, it‟s too small (<0.5d), The weight on the platform is...
  • Page 33: Replacement Part

    User Manual Stainless Steel Drum Scale 1 1 0 0 . . R R e e p p l l a a c c e e m m e e n n t t p p a a r r t t P P a a r r t t N N u u m m b b e e r r D D e e s s c c r r i i p p t t i i o o n n 318529...

Table of Contents