Page 13
中文 AE5106/AE5106-3 安装解锁钢丝绳 解锁钢丝绳如下图所示安装 : - 注意: a. 要求钢丝绳调节至主副立柱上的保险张合一致。 b. 保险与轴之间应加注通用锂基润滑脂 (GB7324-87) , 正常使用时保证保险安全可靠, 如保险不能复位, 应立即停机,不得举升作业,待问题排除后方可使用 c. 保险钢丝绳除两固定端、绳轮外,不得与立柱中任何静止或运动的件相接触。 - 空载测试调整 a. 清理场地,地面不可以有油污,举升机空载。 b. 接通电源,按上升按钮,滑台上升,任意位置停止上升,按回油手柄,将左右滑台落入同档保险 c. 拧紧平衡钢丝绳螺母,使两根平衡钢丝绳松紧度基本一致。 d. 按上升按钮,使滑台上升一段距离,脱离保险,左手拉保险手柄,右手按回油手柄使滑台下降到 最低处。 e. 按上升按钮,全程举升,任意位置触动限位开关,电机停止运转,达到极限位置时溢流阀打开, 液压系统回油,滑台停止上升,举升过程观察左右滑台托臂同步性,如果有明显差异,继续调整 平衡钢丝绳螺母松紧达到左右滑台同步性。 f. 安装车门防撞橡胶垫。 - 负载测试调整 a. 将四个托臂完全打开,确保车道空间无任何障碍。 b. 将汽车驶入举升机, 左右居中, 以立柱连线做参考, 车辆前后放置距离比大致 2:3 ( 前置发动机车辆) ,...
中文 AE5106/AE5106-3 Chapter I Safety precautions - Read the instructions before using the lift, including installation, operation, safety and other related content. - In case of any problem with the lift, stop using it. - Do not overload the lift, which has a rated load of 4000KG.
中文 AE5106/AE5106-3 Chapter II Product Characteristics and Parameters Product features: - 3-section corbel design for a wide range of models - Unilateral manual unlocking, which is safe and reliable - The tray height is adjusted by thread, and the adjustable height is 75mm...
Page 25
中文 AE5106/AE5106-3 Major component introduction: - This machine is mainly composed of main column, auxiliary column, sliding table, corbel, lock arm device, corbel lock, mechanical lock, oil cylinder, power unit, cross beam and so on. (See the figure below) Column: Basic components: Used to install sliding table, oil cylinder and other driving devices...
中文 AE5106/AE5106-3 Chapter III Installation preparation Unpacking - Open the packing case and remove the surrounding packing materials. Check whether the machine is damaged during transportation. Check whether the main and accessories are complete according to the packing list. Keep packing materials away from children to avoid danger;...
中文 AE5106/AE5106-3 Chapter IV Installation Guidance - First of all, select the area to be installed, try to T wall, close to the power supply. - Clean up the hoisting machine installation area, without oil stain on the ground - The product installation space size diagram is for reference...
Page 29
中文 AE5106/AE5106-3 - Place the main column, drill holes with a hammer drill, clean up residual dust in the bolt holes with a vacuum cleaner, and hammer the expansion bolts into the holes - The height of the expansion bolts above the ground cannot be greater than 50mm. Do not tighten the nuts.
Page 30
中文 AE5106/AE5106-3 Install the balance wire rope - Ensure that the left and right sliders are at the first safety gear, and install the balance wire rope according to the indicated track. Do not tighten the nut first, and then adjust the tightness of the two wire ropes when adjusting the synchronization.
Page 31
中文 AE5106/AE5106-3 Power unit assembly - Install the power unit on the motor plate of the main column and fix it with bolts and nuts. Install the limit switch and connect the wire. - Hydraulic system connection c.Unscrew the oil tank cover and pour in 10L-- 46# anti-wear hydraulic oil. (46# anti-wear hydraulic fluid is preferred, and 32# is considered when the temperature is below -10°...
Page 32
中文 AE5106/AE5106-3 l.Install door anti-crash rubber pads. Load test adjustment e.Open the four corbels completely to ensure that the lane space is free of any obstacles. f.Drive the car into the lifter, center the left and right by taking the column connection as a reference; the distance between the front and back of the vehicle is about 2:3 (for front-engine vehicle).
中文 AE5106/AE5106-3 Chapter V Maintenance Guidance - Items to be checked daily e.Check all hydraulic joints, tubing, and cylinders for oil leakage. f.Check all electrical connections for breakage. g.Check all moving parts for wear and tear. h.Clean up the oil on the rubber tray and observe whether there is excessive wear on the rubber tray.
中文 AE5106/AE5106-3 Chapter VI S/N FAQ Solutions The button doesn't work Change the button The contactor cannot be actuated Change the contactor when energized The contactor cannot be energized Check the button and limit switch for actuation Oil leaks from hydraulic system...
中文 AE5106/AE5106-3 Chapter VIII Electrical diagram Note: For power inlet U V W, please use power cable of over 2.5 mm2 For motor interface X Y Z, connect the travel switch J E to the C63 air leakage switch.
Page 37
中文 AE5106/AE5106-3 Wiring mode of motor wire (this wire has been left outside the wire control box) : Red, blue and green wires are live. The yellow wire is for grounding, and the arrow indicates the position of the ground wire.
Page 39
中文 AE5106/AE5106-3 SATA No. Part name Quantity PAE5106-1 Main column welding components PAE5106-2 Auxiliary column welding components PAE5106-3 Right-angle connector PAE5106-4 Housing A PAE5106-5 Bottom of oil groove plate PAE5106-6 Top of oil groove plate PAE5106-7 Gantry sliding table welding assembly...
Page 40
中文 AE5106/AE5106-3 SATA No. Part name Quantity PAE5106-35 Short rocker arm column C PAE5106-36 Tray component PAE5106-37 Long rocker arm column B PAE5106-38 Long rocker arm column A PAE5106-40 8-shaped wire rope clip PAE5106-41 E-type buckle PAE5106-42 Unlocking wire rope...
Need help?
Do you have a question about the AE5106 and is the answer not in the manual?
Questions and answers