Page 13
中文 AE5105/AE5105-3 - 液压系统连接 a. 拧开油箱盖,倒入 10L---46# 抗磨液压油。(首选 46# 抗磨液压油,温度 -10° C 以下,考虑 32#) b. 连接好液压接头,将油管连接于主副油缸出油口接头处。 - 空载测试调整 a. 清理场地,地面不可以有油污,举升机空载。 b. 接通电源,按上升按钮,滑台上升,任意位置停止上升,按回油手柄,将左右滑台落入同档保险 c. 拧紧平衡钢丝绳螺母,使两根平衡钢丝绳松紧度基本一致。 d. 按上升按钮,使滑台上升一段距离,脱离保险,左手拉保险手柄,右手按回油手柄使滑台下降到 最低处。 e. 按上升按钮,全程举升,任意位置触动限位开关,电机停止运转,达到极限位置时溢流阀打开, 液压系统回油,滑台停止上升,举升过程观察左右滑台托臂同步性,如果有明显差异,继续调整 平衡钢丝绳螺母松紧达到左右滑台同步性。 f. 安装车门防撞橡胶垫。 - 负载测试调整 a. 将四个托臂完全打开,确保车道空间无任何障碍。 b. 将汽车驶入举升机, 左右居中, 以立柱连线做参考, 车辆前后放置距离比大致 2:3 ( 前置发动机车辆) ,...
中文 AE5105/AE5105-3 Chapter I Safety Precautions - Make sure that you have read the User's Manual completely including relevant instructions on installation, operation and safety before operating the lift. - Do not use the lift if any abnormality is found in the lift.
中文 AE5105/AE5105-3 Chapter II Product Features and Parameters 2. 1 Product Features: - 2 sections of bracket arms, suitable for a wide range of models - Bilateral manual unlocking, safe and reliable - Tray height adjusted by thread, with the adjustable height of 70mm - Minimum lifting height of 110mm, suitable for low riders 2.2 Technical parameters:...
Page 24
中文 AE5105/AE5105-3 Diagram of product (unit: mm)
Page 25
中文 AE5105/AE5105-3 2.3 Description of main components - This machine mainly consists of the main post, auxiliary post, sliding table, bracket arm, arm lock, bracket arm lock, mechanical lock, cylinder, power unit, gantry, etc. (See the figure below) Post: Basic component, carrying sliding table, cylinder and other drive devices;...
中文 AE5105/AE5105-3 Chapter III Preparation for Installation 3.1 Unpacking - Open the packing case, remove the surrounding packing materials, inspect the machine for damage during transportation, and inspect the main components and accessories for completeness as per the packing list. Keep packing materials away from children so as not to pose any danger, and properly dispose them if they may cause pollution.
中文 AE5105/AE5105-3 Chapter IV Installation Instructions - Determine the mounting position, which shall be close to wall and power as much as possible. - Thoroughly clean the mounting position of the lift, which shall be free from oil stains. - The dimension diagram of mounting space of the product is given below for reference only.
Page 29
中文 AE5105/AE5105-3 - Properly position the main post, drill holes with the impact drill, remove the dust in the bolt hole with a vacuum cleaner, and hammer the expansion bolt into the hole. The length of the expansion bolt protruding from the ground shall not exceed 50mm, and the nut shall not be tightened.
Page 30
中文 AE5105/AE5105-3 - Installation of balance wire rope Make sure that the left and right sliding tables are at the first safety position, and then install the balance wire rope as per the track shown in the figure. Do not tighten the nut temporarily as the tension of two wire ropes will be adjusted for synchronization later on.
Page 31
中文 AE5105/AE5105-3 - Connection of hydraulic system a. Unscrew the hydraulic tank cap and add 10L 46# anti-wear hydraulic oil. (46# anti-wear hydraulic oil is preferred; 32# anti-wear hydraulic oil is preferred at a temperature below -10° C) b. Connect the hydraulic joint and connect the oil pipe to the oil outlet joint of the main and auxiliary cylinders.
中文 AE5105/AE5105-3 Chapter V Maintenance Instructions - Daily maintenance a. Inspect all hydraulic joints, oil pipes, and cylinders for leakage. b. Inspect all electric wires for damage. c. Inspect all moving parts for excessive wear. d. Remove the oil stains on the rubber tray and inspect the rubber tray for excessive wear.
中文 AE5105/AE5105-3 Chapter VI Common Faults S/N Common Faults Solution Button fails to work Replace the button Contactor fails to operate after energization Replace the contactor The contactor fails to be energized and Inspect the button and limit switch operate...
中文 AE5105/AE5105-3 Chapter VIII Electrical Schematic Diagram The power supply is introduced into the contactor entry terminal on the motor and connected to the control line according to the electrical schematic, and the lift of the finite switch also needs to be connected to the limit switch.